Reinraum Tür Positionssensor
- Non-Contact Magnetic Sensing
- Sealed Reed Contact
- Dry-Contact Controller Output
- Interlock Feedback
Produkteinführung
The cleanroom door position sensor pairs a reed-switch module on the frame with a permanent magnet on the moving leaf. When the door closes and the two housings align within the sensing gap, the magnetic field changes the dry contact state sent to the interlock or access controller. Stainless or smooth white housings protect the encapsulated components, and the absence of a mechanical plunger removes a contact point from the clean opening.
Key Features
Encapsulated reed contacts resist contamination at the sensing element and require no exposed actuator.
Separate sensor and magnet housings accommodate frame-to-leaf movement across a controlled gap.
Dry-contact wiring integrates with interlocks, access panels and local door-status indicators.
Kunden Produktbedenken
The control system must distinguish a physically closed door from one that is merely locked or moving through the frame.
Typische Anwendungen
Technische Parameter
Typical dimensions and material data for a sealed cleanroom magnetic door contact are listed below.
| Core Material | Hermetically sealed reed capsule with copper-alloy contacts and ferrite permanent magnet |
|---|---|
| Panel Dicke | Approximately 12–25 mm housing depth |
| Effektive Breite | Approximately 19–38 mm module width |
| Maximale Länge | Approximately 110 mm for a long-range stainless sensor module |
| Stahl facing Dicke | 0.8–1.2 mm brushed stainless-steel housing where selected |
| Kerndichte | Approximately 4800–5100 kg/m³ for the ferrite magnet core |
| Thermische Leitfähigkeit | Approximately 3–5 W/(m·K) for the ferrite magnet material |
| Oberfläche Finish | Brushed stainless steel or smooth white moulded polymer housing |
| Gemeinsamer Typ | Matched surface or recessed sensor-and-magnet pair aligned across a controlled gap |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Cleanroom Door Position Sensor specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch