Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Unidad de condensación refrigerada por agua por

A skid-mounted refrigeration package that transfers cleanroom DX cooling heat into a condenser-water circuit for quiet indoor mechanical-room installation.
  • Compact Skid Package
  • Water-Side Heat Rejection
  • Low Indoor Sound
  • Accessible Refrigerant Circuit
Solicite un presupuesto. Browse productos

Introducción del producto

This water-cooled condensing package integrates a scroll compressor, shell-and-tube condenser, receiver, refrigerant accessories and electrical controls on one rigid base. Cooling water removes compressor heat through the condenser while liquid refrigerant feeds a remote DX air-handler coil. The absence of outdoor condenser fans reduces footprint and sound, making the format useful where a building condenser-water loop is already available.

Características clave

A shell-and-tube condenser provides stable heat transfer to a treated condenser-water circuit.

Skid piping includes receiver, filter-drier, sight glass and isolation points arranged for service access.

Compact compressor and control placement suits indoor plantrooms with restricted outdoor equipment space.

Removable water-box covers permit inspection of the condenser tube sheet and mechanical cleaning access.

Preocupaciones del producto del cliente

An indoor condensing package must balance compactness, water-side serviceability and stable refrigerant delivery to a remote evaporator.

Outdoor equipment space or allowable sound is limited.The unit rejects heat to building water and operates without large condenser fans.
Condenser tubes gradually collect scale or suspended solids.A removable end cover provides direct tube-sheet access for inspection and cleaning.
Field-built refrigeration skids create inconsistent component layouts.Factory assembly places the compressor, receiver, controls and service valves on one tested structural base.
Variable condenser-water temperature can destabilize head pressure.Water-flow control and refrigerant safeties maintain an appropriate condensing range as the loop changes.

Aplicaciones típicas

Hospital cleanroom air handlersHigh-rise laboratory HVACPharmaceutical plants with central cooling towersIndoor process-cooling skidsNoise-sensitive clean manufacturing facilities

Parámetros técnicos

Typical construction data for a compact water-cooled cleanroom refrigeration skid are shown below.

Materiales CoreSteel skid with scroll compressor and copper-tube steel-shell condenser
Panel de espesor1.0-1.5 mm electrical cabinet and equipment guard panels
Ancho efectivo700-1600 mm typical skid width
Longitud máximaUp to 3200 mm for multi-circuit packages
Acero frente a espesor1.2-2.0 mm control enclosure and removable guards
Densidad CoreApproximately 7800-7900 kg/m³ for carbon-steel skid and condenser-shell material
Conductividad térmicaApproximately 45-55 W/(m·K) for carbon-steel condenser shell material
Superficie acabadaEpoxy-painted steel base, coated cabinet and insulated suction piping
Tipo conjuntoWelded skid, flanged water connections and brazed copper refrigerant joints
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Single or tandem scroll compressorShell-and-tube or brazed-plate condenserWater-regulating valve and flow switchDual refrigerant circuits and remote BMS contacts

Planning a Water-Cooled Condensing Unit specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto