Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Sistemas de utilidad de Cleanroom / Purified Water Distribution Loop
Sistemas de utilidad de Cleanroom

Bucle de distribución de agua purificada por

A hygienic circulation and monitoring skid for delivering Purified Water through a continuously moving supply-and-return loop.
  • Continuous hygienic circulation
  • Drainable point-of-use branches
  • Integrated pressure, temperature and conductivity monitoring
Solicite un presupuesto. Browse productos

Introducción del producto

The packaged loop skid connects a Purified Water storage vessel to the facility supply and return headers. A sanitary centrifugal pump maintains circulation, while short drainable branch assemblies provide controlled point-of-use access. Online instruments track hydraulic and water-condition trends, and the local cabinet coordinates pump speed, alarms and interfaces to the upstream generation system.

Características clave

316L stainless supply and return headers

Hygienic centrifugal circulation pump

Short drainable diaphragm-valve branches

Variable-speed flow and pressure control

Online conductivity, temperature and pressure instruments

Low-hold-up sanitary fittings and return bends

Compact stainless control cabinet

Skid-mounted layout for factory assembly

Preocupaciones del producto del cliente

Distribution quality depends on sustaining circulation, controlling branch geometry and matching pump operation to changing point-of-use demand.

Low-demand periods create stagnant sectionsMaintain continuous return flow and use short drainable branches with valves located close to the circulating header.
Pressure falls when several users openUse measured loop pressure and variable-speed pump control sized against the full hydraulic profile.
Water-condition changes are detected too lateMonitor return conductivity and temperature continuously and trend deviations at the local control panel.
Complex field piping is difficult to inspectPreassemble the pump, instruments, hygienic headers and defined branch manifold on an open stainless skid.

Aplicaciones típicas

Oral solid dosage manufacturingNon-sterile liquid pharmaceutical productionBiotechnology buffer preparationCosmetic purified-water utilitiesNutraceutical and laboratory PW networks

Parámetros técnicos

Header size, pump duty and branch count are selected from loop length, elevation, peak draw-off, return-flow target and sanitization strategy.

Materiales Core316L stainless steel product-contact tube, fittings, valve bodies and pump wetted parts
Panel de espesorControl-cabinet and skid sheet components typically 1.5–3.0 mm
Ancho efectivoPackaged skid width typically 900–2200 mm
Longitud máximaPackaged circulation module length typically up to 4000 mm
Acero frente a espesorStainless cabinet facing typically 1.5–2.0 mm
Densidad Core316L stainless steel density approximately 8000 kg/m³
Conductividad térmica316L stainless steel approximately 15 W/(m·K) at ambient temperature
Superficie acabadaHygienic polished product-contact surfaces with satin external skid and cabinet finish
Tipo conjuntoOrbital-welded main tubing with drainable sanitary clamp connections at serviceable components
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Duty and standby circulation pumpsVariable-frequency pump driveConductivity, TOC and temperature instrumentsAutomated point-of-use valvesAmbient or hot-water sanitization interfaceLoop return heat exchangerRemote alarm and data interfaceCustom branch count and header size