Caja de paso dinámico filtrada HEPA
An active transfer cabinet that recirculates filtered air through its interlocked material chamber.
- Internal HEPA Recirculation
- Ceiling Clean-Air Supply
- Low-Level Return Slots
- Filter Status Monitoring
Introducción del producto
The dynamic pass box adds a self-contained fan and final-filter circuit to a double-door transfer chamber. Air returns from the lower chamber area, passes through filtration and re-enters via a ceiling diffuser to condition the payload zone. The internal loop avoids a building supply duct and can run a timed purge after the loading door closes.
Características clave
A broad ceiling diffuser supplies air across the payload footprint.
Low-level return slots collect particles released from packaging.
A filter-pressure indicator provides a maintenance signal.
Door logic can include a purge period before receiving-side access.
Preocupaciones del producto del cliente
Active transfer needs to remove particles generated inside the chamber without complicating room air balancing.
Carton surfaces shed particles after the dirty-side door closes.Repeated filtered recirculation sweeps the chamber before release.
One supply grille leaves stagnant zones around containers.A ceiling diffuser and distributed returns broaden the chamber airflow path.
A duct connection is difficult in a retrofit wall.The self-contained loop needs no room supply or return duct.
Filter loading quietly reduces the airflow.A differential-pressure display indicates rising filter resistance.
Aplicaciones típicas
Sterile material transferBiotechnology suitesMedical-device assemblyAseptic packaging support
Parámetros técnicos
Representative construction ranges for a HEPA-filtered dynamic pass box are shown below.
| Materiales Core | SUS 304 double-wall chamber with EC fan, prefilter, HEPA filter and perforated return channels |
|---|---|
| Panel de espesor | 80-150 mm service-plenum construction |
| Ancho efectivo | 500-1200 mm clear chamber width |
| Longitud máxima | Up to 1500 mm chamber depth |
| Acero frente a espesor | 1.0-1.5 mm stainless-steel facing |
| Densidad Core | 35-40 kg/m³ polyurethane insulation around enclosed service plenums |
| Conductividad térmica | 0.022-0.028 W/(m·K) for polyurethane plenum insulation |
| Superficie acabada | Brushed or electropolished stainless chamber with smooth perforated airflow panels |
| Tipo conjunto | Sealed double-wall cabinet with interlocked gasketed doors and removable filter-access panel |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
H13 or H14 final filterConstant-airflow controlRoom-side pressure displayWall-mounted or floor-supported body