Personal und Material Dekontamination Ausrüstung
HEPA-filterte Dynamische Passbox
An active transfer cabinet that recirculates filtered air through its interlocked material chamber.
- Internal HEPA Recirculation
- Ceiling Clean-Air Supply
- Low-Level Return Slots
- Filter Status Monitoring
Produkteinführung
The dynamic pass box adds a self-contained fan and final-filter circuit to a double-door transfer chamber. Air returns from the lower chamber area, passes through filtration and re-enters via a ceiling diffuser to condition the payload zone. The internal loop avoids a building supply duct and can run a timed purge after the loading door closes.
Key Features
A broad ceiling diffuser supplies air across the payload footprint.
Low-level return slots collect particles released from packaging.
A filter-pressure indicator provides a maintenance signal.
Door logic can include a purge period before receiving-side access.
Kunden Produktbedenken
Active transfer needs to remove particles generated inside the chamber without complicating room air balancing.
Carton surfaces shed particles after the dirty-side door closes.Repeated filtered recirculation sweeps the chamber before release.
One supply grille leaves stagnant zones around containers.A ceiling diffuser and distributed returns broaden the chamber airflow path.
A duct connection is difficult in a retrofit wall.The self-contained loop needs no room supply or return duct.
Filter loading quietly reduces the airflow.A differential-pressure display indicates rising filter resistance.
Typische Anwendungen
Sterile material transferBiotechnology suitesMedical-device assemblyAseptic packaging support
Technische Parameter
Representative construction ranges for a HEPA-filtered dynamic pass box are shown below.
| Core Material | SUS 304 double-wall chamber with EC fan, prefilter, HEPA filter and perforated return channels |
|---|---|
| Panel Dicke | 80-150 mm service-plenum construction |
| Effektive Breite | 500 - 1200 mm klare Kammerbreite |
| Maximale Länge | bis zu 1500 mm Kammertiefe |
| Stahl facing Dicke | 1,0 - 1,5 mm Edelstahl-Verschnitte |
| Kerndichte | 35-40 kg/m³ polyurethane insulation around enclosed service plenums |
| Thermische Leitfähigkeit | 0,022 - 0,028 W / (m · K) für Polyurethan-Plenumdämmung |
| Oberfläche Finish | Brushed or electropolished stainless chamber with smooth perforated airflow panels |
| Gemeinsamer Typ | Sealed double-wall cabinet with interlocked gasketed doors and removable filter-access panel |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
H13 or H14 final filterConstant-airflow controlRoom-side pressure displayWall-mounted or floor-supported body
Planning a HEPA-Filtered Dynamic Pass Box specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.