Sistem Dehumidification Bilik Kering

An integrated high-recirculation air-treatment system that controls the complete moisture balance of a production dry room, including infiltration, occupants and process exhaust replacement.
  • Room-Wide Moisture Balance
  • High Recirculation Airflow
  • Dedicated Infiltration Control
  • Integrated Temperature Reset
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The dry-room dehumidification system is sized around the room envelope, personnel traffic, process exhaust and material transfer rather than a single equipment outlet. It combines filtered return-air recirculation, a low-dew-point desiccant section, outdoor-air treatment, cooling and final temperature reset. Supply and return dew-point sensors feed a central controller that preserves stable room conditions while airlocks and exhaust points introduce changing moisture loads.

Ciri-ciri Utama

A high recirculation ratio repeatedly captures moisture released by personnel, products and door openings before it accumulates in the room.

Separate make-up and return-air paths let the controller treat humid infiltration more aggressively than already dry recirculated air.

Multiple fan and coil sections can be arranged for service continuity without stopping the entire dry-room airflow.

Return-air dew-point measurement represents the room moisture condition and prevents misleading control from an unusually dry supply sample.

Kebimbangan Produk Pelanggan

A dry room behaves as a complete moisture-control envelope, so equipment selection must address people, openings, exhaust and surface leakage together.

The supply air reaches its target but the occupied room dew point rises near doors and workstations.High-volume recirculation and distributed supply-return placement sweep local moisture back to the central drying system.
Process exhaust removes conditioned air and pulls humid building air through the envelope.Metered ultra-dry make-up air offsets exhaust while room-pressure control limits uncontrolled infiltration.
A planned filter or fan service event threatens to stop moisture-sensitive production.Parallel fans, isolated filter banks and sectional dampers allow selected components to be maintained while the remaining path operates.
Extremely dry supply air carries excess sensible heat from rotor regeneration and fan power.Dedicated aftercooling and staged chilled-water control remove process heat without adding moisture back to the airstream.

Permohonan yang biasa

Lithium-ion cell manufacturing dry roomsBattery electrolyte preparation and fillingMoisture-reactive chemical packagingAdvanced battery research pilot linesHygroscopic pharmaceutical production rooms

Parameter teknikal

Representative structural ranges for a central dry-room dehumidification and recirculation package are shown below.

Bahan TerasLow-dew-point composite desiccant rotor with mineral-wool-insulated galvanized or stainless air-handling modules
Ketebalan Panel60-100 mm thermally broken double-skin panel construction
Lebar berkesan2200-4800 mm nominal system module width
Panjang maksimumUp to 12000 mm for combined recirculation drying cooling and fan sections
Keluli Menghadapi Ketebalan0.8-1.5 mm coated galvanized or stainless casing skins
Ketumpatan teras60-100 kg/m³ typical high-density mineral-wool panel insulation
Kekonduksian TermaApproximately 0.035-0.043 W/(m·K) for high-density mineral-wool panel insulation
Kemasan permukaanBlue powder-coated exterior with smooth galvanized or 304 stainless internal air surfaces
Jenis BersatuBolted gasketed modules with thermally broken frames, low-leakage dampers and sealed duct flanges
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Duty-standby process fans and isolated filter banksAir-cooled DX or chilled-water temperature-control sectionsElectric steam or gas reactivation with heat recoveryRoom pressure dew-point and energy monitoring through a central PLC