ホーム / 製品 / クリーンルーム空気分配システム / Single-Duct VAV Reheat Terminal Unit
クリーンルーム空気分配システム

単一ダクト VAV の再熱ターミナルユニット

A pressure-independent single-duct terminal that meters primary air and reheats the minimum airflow before discharge to a perimeter or process-support zone.
  • Pressure-Independent VAV Control
  • Integral Hot-Water or Electric Reheat
  • Averaging Inlet Flow Sensor
  • Acoustically Lined Casing
見積もりリクエスト 製品案内

商品紹介

The single-duct VAV reheat terminal unit combines a round primary-air inlet, averaging flow sensor, modulating damper and rectangular discharge casing with an integral heating section. During cooling demand, the controller varies primary airflow between programmed minimum and maximum values. When the zone requires heat, airflow is held at the heating minimum while a hot-water valve or staged electric heater raises the discharge temperature. An acoustic liner and optional attenuator control regenerated noise, while coil access panels support inspection of the downstream heating section.

主要な特徴

An averaging inlet sensor and matched controller maintain primary airflow as duct static pressure changes.

Hot-water or electric reheat adds sensible heat downstream of the control damper without a terminal fan.

Programmed cooling, ventilation and heating minimums allow airflow to follow the zone operating sequence.

Acoustic lining and optional discharge attenuator reduce radiated and air-path noise above occupied spaces.

お客様の製品に関する懸念事項

A reheat terminal must preserve required ventilation airflow, prevent discharge overheating, control noise and keep the heating coil and controller accessible above the ceiling.

Reducing cooling airflow below the ventilation minimum compromises room air exchange.Separate programmed cooling and occupied minimums keep primary air above the required ventilation quantity.
Reheat energizes at too little airflow and produces excessive discharge temperature.Airflow proof and a defined heating minimum enable the coil or heater only when sufficient air passes through the box.
High inlet static pressure produces objectionable regenerated noise over the room.Correct inlet sizing, duct-pressure reset and acoustic attenuation limit velocity and throttling sound.
A leaking water coil valve causes simultaneous cooling and heating energy waste.A tight-closing modulating valve and discharge-air temperature monitoring expose unintended heat input.

典型的な用途

Cleanroom perimeter support zonesLaboratory offices and write-up roomsHospital patient and support spacesPharmaceutical corridors and gowning roomsCommercial zones with central cool air

技術的なパラメータ

Representative casing construction ranges for a single-duct VAV terminal with integral reheat are shown below.

コア材料32–48 kg/m³ mineral-fiber acoustic liner behind galvanized casing with copper-tube aluminum-fin reheat coil
パネルの厚さ13–25 mm internal acoustic liner
有効幅300–1000 mm nominal terminal casing width
最大長さUp to 1800 mm combined terminal, attenuator and reheat-section length
鋼鉄の厚さを直面する0.7–1.0 mm galvanized casing and access panels
コア密度32–48 kg/m³ mineral-fiber acoustic lining
熱伝導率Approximately 0.035–0.045 W/(m·K) for the acoustic liner
表面仕上げMill-galvanized casing with cleanable liner facing and corrosion-protected coil frame
ジョイントタイプRound inlet to rectangular lined casing with integral sensor, damper and flanged downstream reheat section
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

One- to four-row hot-water reheat coilStaged or proportional electric heaterIntegral discharge attenuatorFactory-mounted DDC controller and valve package