Accueil / Produits / Systèmes de distribution d'air Cleanroom / Single-Duct VAV Reheat Terminal Unit
Systèmes de distribution d'air Cleanroom

Unité terminale de réchauffement VAV à conduit unique

A pressure-independent single-duct terminal that meters primary air and reheats the minimum airflow before discharge to a perimeter or process-support zone.
  • Pressure-Independent VAV Control
  • Integral Hot-Water or Electric Reheat
  • Averaging Inlet Flow Sensor
  • Acoustically Lined Casing
Demander un devis. Browse les produits

Introduction de produit

The single-duct VAV reheat terminal unit combines a round primary-air inlet, averaging flow sensor, modulating damper and rectangular discharge casing with an integral heating section. During cooling demand, the controller varies primary airflow between programmed minimum and maximum values. When the zone requires heat, airflow is held at the heating minimum while a hot-water valve or staged electric heater raises the discharge temperature. An acoustic liner and optional attenuator control regenerated noise, while coil access panels support inspection of the downstream heating section.

Key Features

An averaging inlet sensor and matched controller maintain primary airflow as duct static pressure changes.

Hot-water or electric reheat adds sensible heat downstream of the control damper without a terminal fan.

Programmed cooling, ventilation and heating minimums allow airflow to follow the zone operating sequence.

Acoustic lining and optional discharge attenuator reduce radiated and air-path noise above occupied spaces.

Préoccupations du client produit

A reheat terminal must preserve required ventilation airflow, prevent discharge overheating, control noise and keep the heating coil and controller accessible above the ceiling.

Reducing cooling airflow below the ventilation minimum compromises room air exchange.Separate programmed cooling and occupied minimums keep primary air above the required ventilation quantity.
Reheat energizes at too little airflow and produces excessive discharge temperature.Airflow proof and a defined heating minimum enable the coil or heater only when sufficient air passes through the box.
High inlet static pressure produces objectionable regenerated noise over the room.Correct inlet sizing, duct-pressure reset and acoustic attenuation limit velocity and throttling sound.
A leaking water coil valve causes simultaneous cooling and heating energy waste.A tight-closing modulating valve and discharge-air temperature monitoring expose unintended heat input.

Les applications typiques

Cleanroom perimeter support zonesLaboratory offices and write-up roomsHospital patient and support spacesPharmaceutical corridors and gowning roomsCommercial zones with central cool air

Paramètres techniques

Representative casing construction ranges for a single-duct VAV terminal with integral reheat are shown below.

Matériaux de base32–48 kg/m³ mineral-fiber acoustic liner behind galvanized casing with copper-tube aluminum-fin reheat coil
Panneau épaisseur13–25 mm internal acoustic liner
Largeur effective300–1000 mm nominal terminal casing width
Longueur maximaleUp to 1800 mm combined terminal, attenuator and reheat-section length
Acier face épaisseur0.7–1.0 mm galvanized casing and access panels
Densité Core32–48 kg/m³ mineral-fiber acoustic lining
Conductivité thermiqueApproximately 0.035–0.045 W/(m·K) for the acoustic liner
surface finieMill-galvanized casing with cleanable liner facing and corrosion-protected coil frame
Type jointRound inlet to rectangular lined casing with integral sensor, damper and flanged downstream reheat section
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

One- to four-row hot-water reheat coilStaged or proportional electric heaterIntegral discharge attenuatorFactory-mounted DDC controller and valve package

Planning a Single-Duct VAV Reheat Terminal Unit specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.