A standalone air-cooled refrigerated dryer that cools compressed air, separates condensed water and reheats the dry outlet stream for general cleanroom utility service.
  • 167 L/s reference inlet flow
  • +3°C pressure dew point class
  • Electronic automatic condensate drain
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The Refrigerated Air Dryer is a self-contained compressed-air treatment cabinet installed downstream of a compressor and wet receiver. Incoming warm, moisture-laden air is first precooled by the outgoing dry stream, then cooled further in a refrigerant-to-air heat exchanger so water vapor condenses. An internal separator removes the liquid and an electronic drain discharges it without making the dryer a storage vessel. The outgoing air is reheated in the air-to-air section to reduce external pipe sweating. The selected medium-capacity unit has one service door, one large condenser-air grille, two top compressed-air connections, a compact dew-point controller and four fixed feet. It contains a hermetic refrigerant compressor and heat exchangers, but no air-compression element, desiccant towers, filter cartridges, air receiver or comfort-air-conditioning ductwork.

Fitur utama:

A combined air-to-air and refrigerant-to-air exchanger recovers cooling from the dry outlet stream before final discharge

The refrigeration circuit supports a stable positive pressure dew point without consuming purge air

An internal condensate separator removes liquid formed at the coldest point of the air path

An electronic level-controlled drain releases collected condensate automatically

A front digital controller provides local dew-point, operating-status and alarm indication

A large lower condenser grille gives the air-cooled refrigeration circuit a direct ventilation path

Two top-mounted air connections keep wet-air inlet and dry-air outlet piping clear of the service door

One hinged front door provides access to the heat exchanger, separator, refrigerant compressor and drain

Kekhawatiran produk pelanggan

Compressed air cools as it moves through plant piping, so water vapor can condense after the compressor unless moisture is removed at a controlled pressure dew point.

Condensate in distribution piping can corrode components and disrupt pneumatic equipmentCool the full air stream to the selected pressure dew point, separate the resulting liquid and discharge it before the air enters the distribution header.
A dryer selected only by nominal compressor output may be undersized at high inlet or ambient temperatureApply manufacturer correction factors for actual inlet flow, pressure, inlet temperature and ventilation conditions before selecting the dryer size.
Blocked condenser airflow can raise refrigerant pressure and destabilize drying performanceKeep the front condenser grille and service clearance unobstructed and include condenser cleaning in routine maintenance.
A failed or obstructed condensate drain can carry separated water back into the outlet airUse the accessible electronic drain, route its discharge visibly and verify drain operation during scheduled inspections.
Users may expect a refrigerated dryer alone to provide sterile or ultra-low-dew-point airTreat the dryer as the moisture-removal stage and select downstream particulate, oil-removal or sterile filtration separately for the required air quality.

Aplikasi yang Tipis

Central cleanroom utility compressed-air stationsPharmaceutical packaging and general pneumatic controlsMedical-device assembly equipmentElectronics production and instrument-air preparationFood and beverage processing utility airGeneral manufacturing where a positive pressure dew point is sufficient

Parameter teknis

The selected catalogue-scale identity is a standalone air-cooled, non-cycling refrigerated dryer sized around 167 L/s at a +3°C pressure dew point, 7 bar reference pressure, 35°C inlet air and 25°C ambient conditions. Its representative cabinet envelope is approximately 898 mm wide by 735 mm deep by 1002 mm high, with two 2-inch female compressed-air connections and a 13 bar maximum working-pressure class. Actual flow capacity, pressure drop, electrical supply, refrigerant, inlet-temperature allowance and drain arrangement depend on the selected model and site conditions.

Bahan intiBrazed aluminum air-to-air and refrigerant-to-air heat exchanger, hermetic refrigerant compressor, condensate separator and powder-coated carbon-steel cabinet
Ketebalan Panel (Panel Thickness)Removable cabinet and service-door assembly typically 20-30 mm including acoustic lining and folded reinforcement
Efektif lebar898 mm overall cabinet width for the selected medium-capacity configuration
Panjang maksimum1002 mm overall cabinet height for the selected configuration
Baja menghadap ketebalanPowder-coated formed carbon-steel outer panels typically 1.0-1.5 mm
Kepadatan inti (core density)Carbon steel approximately 7850 kg/m³
Konduktivitas Termal (Thermal Conductivity)Carbon steel approximately 48 W/(m·K) at 20°C
Permukaan selesaiFine-textured RAL 7035 light-gray powder-coated cabinet, graphite condenser grille and feet, blue controller bezel, natural aluminum exchanger and copper refrigerant tubing
Jenis BersamaTwo top-mounted 2-inch female compressed-air ports, brazed internal refrigerant joints and one threaded electronic condensate-drain outlet
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Alternative flow capacities for the corrected operating conditions+3°C or +5°C nominal pressure dew point selectionAlternative maximum working-pressure classesSingle-phase or three-phase electrical supplyAir-cooled or water-cooled condenser configurationElectronic level-controlled or zero-loss condensate drainRemote alarm contacts and communication interfaceHigh-inlet-temperature versionMatching upstream water separator and downstream compressed-air filters