Stasiun Pengukuran Aliran Udara Duct
- Multi-Point Velocity Traverse
- Low-Airflow Measurement
- Remote Digital Transmitter
- Supply or Exhaust Monitoring
Perkenalan produk
The duct airflow measuring station uses several bead-in-glass thermal sensors distributed across the duct cross-section to capture a representative velocity traverse. Each node compares a heated element with a reference temperature element, and the remote transmitter combines the readings with the entered duct area to calculate volumetric or mass airflow. Stainless-steel probes, plenum-rated cables and an external display enclosure suit permanent installation where operators need more than a one-time balancing reading. Analog and network outputs can feed room-pressure control, air-change verification or maintenance trending.
Fitur utama:
Thermal-dispersion measurement operates at the low duct velocities common in ventilation and pressure-tracking branches.
A remote transmitter displays airflow and temperature while isolating electronics from the active duct section.
Selectable analog and serial communications support connection to airflow alarms or a building control system.
Kekhawatiran produk pelanggan
Reliable airflow control depends on a measurement point that represents the whole duct profile and remains stable at low velocity.
Aplikasi yang Tipis
Parameter teknis
Typical construction and dimensional ranges for a permanent multi-point duct airflow station are listed below.
| Bahan inti | 304 stainless-steel probe tubes with hermetically sealed thermistor nodes and plenum-rated sensor cables |
|---|---|
| Ketebalan Panel (Panel Thickness) | 1.0–2.0 mm stainless probe supports and mounting plates |
| Efektif lebar | 100–2500 mm duct traverse width using one or more probes |
| Panjang maksimum | Up to 2500 mm active probe length for rectangular duct arrays |
| Baja menghadap ketebalan | 1.0–2.0 mm stainless mounting flange and probe bracket |
| Kepadatan inti (core density) | Approximately 8000 kg/m³ for 304 stainless-steel probe components |
| Konduktivitas Termal (Thermal Conductivity) | Approximately 14–16 W/(m·K) for 304 stainless-steel probe components |
| Permukaan selesai | Clean passivated stainless probes with powder-coated remote transmitter enclosure |
| Jenis Bersama | Duct-insertion compression flange with sealed cable glands to a remote transmitter |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a Duct Airflow Measuring Station specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.