Detektor Asap Ruang Bersih

A low-profile optical detector with a cleanable housing and sealed ceiling interface for controlled environments.
  • Low-Profile Cleanable Housing
  • Addressable or Conventional Base
  • Selectable Sensitivity
  • Remote Indicator Option
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The cleanroom smoke detector encloses an optical sensing chamber in a smooth low-profile housing fixed to a sealed mounting base. Addressable electronics can report device identity, contamination level and alarm status to the fire panel, while selectable sensitivity helps balance early response against nuisance sources. A removable detector head supports scheduled service without disturbing the ceiling cable entry.

Fitur utama:

Optical chamber responds to airborne combustion particles.

Smooth exposed surfaces support routine wipe-down.

A twist-lock head separates from the fixed wired base for service.

Addressable versions report device and maintenance status.

Kekhawatiran produk pelanggan

High airflow and strict cleaning requirements demand a detector that remains serviceable without creating an untidy ceiling penetration.

Air movement can dilute smoke at a passive detector.Detector spacing and sensitivity are coordinated with the room airflow pattern and fire design.
Dust accumulation raises nuisance-alarm risk.Chamber compensation and maintenance reporting identify gradual contamination.
Ceiling service can disturb clean finishes.The detector head removes from a permanently sealed wired base.
Operators need to locate an alarmed device quickly.Addressable identity and an optional remote LED provide clear location status.

Aplikasi yang Tipis

Cleanroom FarmasiBioteknologi SuiteProduksi perangkat medisLaboratorium yang dikendalikan

Parameter teknis

Typical detector-housing construction values are listed below; final sensing and listing requirements follow the fire-alarm design.

Bahan intiFlame-retardant white engineering polymer with stainless mounting plate
Ketebalan Panel (Panel Thickness)2.0-3.0 mm molded housing wall
Efektif lebar90-130 mm detector diameter
Panjang maksimumUp to 70 mm installed depth
Baja menghadap ketebalan0.8-1.2 mm internal stainless mounting plate
Kepadatan inti (core density)1200-1450 kg/m³ for polymer housing
Konduktivitas Termal (Thermal Conductivity)0.18-0.30 W/(m·K) for polymer housing
Permukaan selesaiSmooth matte white cleanable housing
Jenis BersamaTwist-lock detector head on gasketed wired mounting base
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Addressable or conventional baseRemote indicatorIsolator baseProtective dust cover

Planning a Cleanroom Smoke Detector specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah