Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Instruments d'essai et de validation de salle blanche

Caméra d'imagerie thermique

A handheld gun-style thermal imaging camera with a radiometric infrared detector, visible-light context, rear color display and trigger capture for non-contact surface-temperature surveys.
  • Radiometric non-contact thermal surveys.
  • Visible-light context and palette control.
  • Emissivity correction and stored analysis data.
Demander un devis. Browse les produits

Introduction de produit

This portable thermal imaging camera converts long-wave infrared radiation from a surface into a radiometric temperature map. An uncooled microbolometer, protected infrared optic and onboard visible-light camera help the operator locate electrical, mechanical, HVAC and enclosure anomalies without contacting the target. The rear color display supports palette selection, spot and area analysis, while adjustable emissivity and reflected-temperature inputs address common surface-measurement variables. Trigger capture stores the thermogram with its measurement data so the original radiometric file can be reviewed and reported after the inspection.

Key Features

Radiometric long-wave infrared detector records a temperature value for every thermal-image pixel.

Visible-light camera supplies recognizable equipment context and supports blended or picture-in-picture viewing.

Center spot plus movable area minimum and maximum tools help screen a surface for localized anomalies.

Adjustable emissivity and reflected-temperature inputs support measurements on materials with different radiative properties.

Multiple palettes and manual or automatic level-and-span settings make subtle temperature patterns easier to distinguish.

One-handed trigger capture, rear color display, protected lens and removable battery suit routine field inspection.

Préoccupations du client produit

Useful thermography depends on surface emissivity, reflected surroundings, focus, viewing distance, spatial resolution and stable operating load; a thermogram shows a surface-temperature pattern that should be interpreted with inspection context.

Low-emissivity metal can reflect surrounding heat and produce a misleading apparent temperature.Set emissivity and reflected temperature for the surface, use a suitable high-emissivity reference patch where permitted, and compare like surfaces from a controlled angle.
A blurred image or excessive working distance can conceal a small thermal anomaly.Use the specified focus method, observe the minimum focus distance, and move close enough for the target to cover multiple detector pixels while maintaining safe clearance.
Automatic color scaling can make similar temperatures look dramatically different between two images.Lock or manually set level and span when comparing assets, and retain the numerical spot or area readings with the thermogram.
A thermal pattern may indicate a surface anomaly without identifying its underlying cause.Store the radiometric and visible images together, document operating load and conditions, then confirm significant findings with the appropriate electrical, mechanical or airflow test.

Les applications typiques

Electrical-panel and control-component temperature surveysAir-handling unit, duct and HVAC distribution checksInsulation, door-seal and building-envelope investigationsMotor, bearing, pump and rotating-equipment screeningProcess-equipment and cleanroom utility troubleshooting

Paramètres techniques

Representative construction for a professional handheld thermal imaging camera is listed below; detector resolution, field of view, focus method, temperature range and communication options should be selected for the intended survey distance and target size.

Matériaux de basePC/ABS gun-style enclosure with TPE grip, uncooled VOx microbolometer, germanium infrared optic, visible-light CMOS camera, color LCD, lithium-ion battery and stainless fasteners
Panneau épaisseurTypically 2.0-3.0 mm for the molded enclosure wall
Largeur effectiveApproximately 90-120 mm across the optical head
Longueur maximaleApproximately 210-260 mm from lens bezel to handle base
Acier face épaisseurTypically 0.5-1.0 mm for internal EMI shielding, fasteners and threaded inserts
Densité CoreEnviron 1100 - 1200 kg / m3 pour le mélange de boîtier PC / ABS
Conductivité thermiqueEnviron 0,19 - 0,22 W / (m · K) pour le mélange de boîtier PC / ABS
surface finieFine-texture graphite PC/ABS body, orange TPE grip and trigger, black lens cap, coated germanium optic and full-color rear LCD
Type jointThreaded or bayonet infrared-lens bezel with hinged protective cap, sealed data-interface cover, slide-lock battery compartment and 1/4-inch tripod insert
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Infrared detector resolutions from survey-grade to higher-detail configurationsFixed-focus or manual-focus infrared opticsWide-angle or telephoto lens configurationVisible-light fusion and picture-in-picture modesRemovable battery, charging cradle and spare-battery kitRadiometric analysis software, data cable, wrist strap and protective case

Planning a Thermal Imaging Camera specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe