Duct isolateur de vibrations
- Low-Frequency Steel Coil Spring
- Neoprene High-Frequency Isolation
- Zinc-Plated Hanger Housing
- Threaded-Rod Misalignment Protection
Introduction de produit
The duct vibration isolator is installed in the threaded-rod suspension path supporting ductwork, inline fans or a trapeze frame. A laterally stable steel coil spring carries the vertical load, while a molded neoprene element and lower spring cup attenuate higher-frequency vibration and prevent the rod from contacting the steel housing. The open hanger frame permits visual confirmation of spring compression after loading. Oversized rod openings accommodate limited angular misalignment so the isolator can deflect freely without creating a metal-to-metal short circuit.
Key Features
A molded neoprene element in series with the spring reduces high-frequency fan and blade-passage transmission.
The open zinc-plated housing allows installers to inspect spring alignment and verify that the coil remains free of the frame.
Oversized rod passages and resilient collars tolerate practical suspension-rod offset without metal contact.
Préoccupations du client produit
Effective isolation depends on matching each hanger to its actual supported load, preserving free spring movement and preventing the threaded rod from touching the steel housing.
Les applications typiques
Paramètres techniques
Representative construction ranges for a spring-and-neoprene duct vibration isolation hanger are listed below.
| Matériaux de base | Laterally stable steel coil spring in series with molded neoprene cap and collar |
|---|---|
| Panneau épaisseur | 1.5–2.5 mm stamped and welded steel hanger housing |
| Largeur effective | 50–100 mm clear housing width for suspended threaded-rod alignment |
| Longueur maximale | 150–300 mm overall hanger height depending on spring deflection and load range |
| Acier face épaisseur | 1.5–2.5 mm zinc-plated steel bracket and load plate |
| Densité Core | Approximately 7850 kg/m³ for the load-bearing spring steel |
| Conductivité thermique | Approximately 45–50 W/(m·K) through the hardened steel coil spring |
| surface finie | Zinc-plated or powder-coated steel housing with color-coded spring and black neoprene elements |
| Type joint | Threaded-rod suspension through an open steel bracket, steel coil spring and neoprene load-distribution cup |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Duct Vibration Isolator specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien