Compteur de particules d'air comprimé
- High-pressure diffusion aligns flow with the counter.
- Low-shedding stainless paths protect sample integrity.
- Gas correction supports portable point checks.
Introduction de produit
This compressed air particle counter combines an optical airborne particle counter with a passivated stainless-steel high-pressure diffuser. The diffuser reduces line pressure to near atmospheric conditions while maintaining a controlled sample flow to the counter, protecting the optical system and avoiding flow-related counting errors. Gas-specific volume correction and isokinetic-style sampling options support meaningful cleanliness assessment for clean dry air, nitrogen and compatible inert gases.
Key Features
Controlled outlet flow matches the connected counter's calibrated sample rate.
Passivated stainless-steel wetted path minimizes particle shedding and chemical interaction.
Gas-specific correction accounts for density differences between calibration air and the sampled gas.
HEPA-protected exhaust reduces contamination ingress when the diffuser is disconnected.
Portable package supports testing at multiple utility points without permanent installation.
Préoccupations du client produit
Pressurized gas must be reduced without adding particles, matched to the counter's intake flow, and interpreted for the density of the sampled gas.
Les applications typiques
Paramètres techniques
The table presents representative enclosure, flow-path, interface, and material configurations for a high-pressure diffuser and connected counter kit, with selection based on gas pressure and sampling point.
| Matériaux de base | Passivated stainless-steel high-pressure diffuser with an optical laser particle counter and HEPA-protected exhaust |
|---|---|
| Panneau épaisseur | Approximately 1.0–1.5 mm for the particle-counter enclosure |
| Largeur effective | Approximately 230–300 mm for the counter and diffuser package |
| Longueur maximale | Approximately 300–550 mm including connected diffuser and short sample tubing |
| Acier face épaisseur | Typically 1.0–1.5 mm for fabricated stainless enclosure surfaces |
| Densité Core | Not applicable; no insulation core is used (0 kg/m³) |
| Conductivité thermique | Approximately 14–16 W/(m·K) for stainless-steel wetted and enclosure components |
| surface finie | Passivated fine-brushed stainless steel with clean compression fittings and a wipe-clean instrument surface |
| Type joint | Compression or VCR gas inlet, controlled diffuser outlet and barbed or direct particle-counter connection |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Compressed Air Particle Counter specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais