เครื่องนับอนุภาคอากาศอัด
- High-pressure diffusion aligns flow with the counter.
- Low-shedding stainless paths protect sample integrity.
- Gas correction supports portable point checks.
การแนะนําสินค้า
This compressed air particle counter combines an optical airborne particle counter with a passivated stainless-steel high-pressure diffuser. The diffuser reduces line pressure to near atmospheric conditions while maintaining a controlled sample flow to the counter, protecting the optical system and avoiding flow-related counting errors. Gas-specific volume correction and isokinetic-style sampling options support meaningful cleanliness assessment for clean dry air, nitrogen and compatible inert gases.
คุณสมบัติที่สําคัญ
Controlled outlet flow matches the connected counter's calibrated sample rate.
Passivated stainless-steel wetted path minimizes particle shedding and chemical interaction.
Gas-specific correction accounts for density differences between calibration air and the sampled gas.
HEPA-protected exhaust reduces contamination ingress when the diffuser is disconnected.
Portable package supports testing at multiple utility points without permanent installation.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
Pressurized gas must be reduced without adding particles, matched to the counter's intake flow, and interpreted for the density of the sampled gas.
การใช้งานทั่วไป
พารามิเตอร์ทางเทคนิค
The table presents representative enclosure, flow-path, interface, and material configurations for a high-pressure diffuser and connected counter kit, with selection based on gas pressure and sampling point.
| วัสดุหลัก | Passivated stainless-steel high-pressure diffuser with an optical laser particle counter and HEPA-protected exhaust |
|---|---|
| ความหนาของแผง | Approximately 1.0–1.5 mm for the particle-counter enclosure |
| ความกว้างที่มีประสิทธิภาพ | Approximately 230–300 mm for the counter and diffuser package |
| ความยาวสูงสุด | Approximately 300–550 mm including connected diffuser and short sample tubing |
| ความหนาของเหล็กหันหน้า | Typically 1.0–1.5 mm for fabricated stainless enclosure surfaces |
| ความหนาแน่นหลัก | Not applicable; no insulation core is used (0 kg/m³) |
| การนําความร้อน | Approximately 14–16 W/(m·K) for stainless-steel wetted and enclosure components |
| เสร็จสิ้นพื้นผิว | Passivated fine-brushed stainless steel with clean compression fittings and a wipe-clean instrument surface |
| ประเภทร่วม | Compression or VCR gas inlet, controlled diffuser outlet and barbed or direct particle-counter connection |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Planning a Compressed Air Particle Counter specification?
ส่งมิติของคุณเงื่อนไขการติดตั้งเป้าหมายประสิทธิภาพและผิวที่ต้องการ

ภาษาอังกฤษ
ภาษาเยอรมัน
ภาษาอาหรับ
ฝรั่งเศส
ภาษาอินโดนีเซีย
ภาษาญี่ปุ่น
ภาษาเกาหลี
ภาษามาเลย์
ภาษาโปรตุเกส
ภาษารัสเซีย
ภาษาสเปน
ภาษาไทยปัจจุบัน
ภาษาตุรกี
ภาษาเวียดนาม