Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Dụng cụ kiểm tra và xác nhận phòng sạch

Máy đếm hạt không khí nén

A particle-counting package with a high-pressure diffuser for measuring particulate contamination in clean compressed-air and inert-gas systems.
  • High-pressure diffusion aligns flow with the counter.
  • Low-shedding stainless paths protect sample integrity.
  • Gas correction supports portable point checks.
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This compressed air particle counter combines an optical airborne particle counter with a passivated stainless-steel high-pressure diffuser. The diffuser reduces line pressure to near atmospheric conditions while maintaining a controlled sample flow to the counter, protecting the optical system and avoiding flow-related counting errors. Gas-specific volume correction and isokinetic-style sampling options support meaningful cleanliness assessment for clean dry air, nitrogen and compatible inert gases.

Các tính năng chính

Pressure-reducing diffuser enables safe particle measurement from compressed-gas lines.

Controlled outlet flow matches the connected counter's calibrated sample rate.

Passivated stainless-steel wetted path minimizes particle shedding and chemical interaction.

Gas-specific correction accounts for density differences between calibration air and the sampled gas.

HEPA-protected exhaust reduces contamination ingress when the diffuser is disconnected.

Portable package supports testing at multiple utility points without permanent installation.

Các mối quan tâm về sản phẩm của khách hàng

Pressurized gas must be reduced without adding particles, matched to the counter's intake flow, and interpreted for the density of the sampled gas.

Direct high-pressure connection can overload or damage a standard particle counter.The dedicated diffuser reduces pressure and delivers the counter's required sample flow near atmospheric conditions.
Different gas densities can distort the calculated sample volume.Gas selection and specific-gravity correction normalize measured flow for the sampled medium.
Pressure reduction hardware may introduce particles into an otherwise clean sample.A passivated stainless wetted path and protected exhaust minimize shedding and contamination ingress.
Large particles may be lost when gas velocity changes abruptly.An isokinetic-style diffuser configuration controls the transition and preserves the sampled size distribution more effectively.

Các ứng dụng điển hình

Clean compressed-air utility qualificationNitrogen and argon particle cleanliness testingPharmaceutical process-gas monitoringElectronics and semiconductor clean dry air assessmentInvestigation of particulate contamination at point-of-use gas outlets

Thông số kỹ thuật

The table presents representative enclosure, flow-path, interface, and material configurations for a high-pressure diffuser and connected counter kit, with selection based on gas pressure and sampling point.

Vật liệu lõiPassivated stainless-steel high-pressure diffuser with an optical laser particle counter and HEPA-protected exhaust
Độ dày bảng điều khiểnApproximately 1.0–1.5 mm for the particle-counter enclosure
Chiều rộng hiệu quảApproximately 230–300 mm for the counter and diffuser package
Chiều dài tối đaApproximately 300–550 mm including connected diffuser and short sample tubing
Thép đối mặt với độ dàyTypically 1.0–1.5 mm for fabricated stainless enclosure surfaces
Mật độ lõiNot applicable; no insulation core is used (0 kg/m³)
Độ dẫn nhiệtApproximately 14–16 W/(m·K) for stainless-steel wetted and enclosure components
Kết thúc bề mặtPassivated fine-brushed stainless steel with clean compression fittings and a wipe-clean instrument surface
Loại khớp nốiCompression or VCR gas inlet, controlled diffuser outlet and barbed or direct particle-counter connection
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

2.83, 28.3, 50 or 100 L/min counter flow0.3 µm or 0.5 µm minimum particle channelCompressed air, nitrogen, argon or carbon-dioxide correctionCompression, VCR or barb process connectionUltra-dry-gas bleed-air diffuser configurationPortable case with regulator, tubing and fittings

Planning a Compressed Air Particle Counter specification?