Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

A Unité de condensation refroidie par air

A factory-assembled outdoor refrigeration unit that rejects cleanroom cooling loads directly to ambient air and supplies liquid refrigerant to a remote DX coil.
  • Direct Ambient Heat Rejection
  • Staged Scroll Compression
  • Weather-Resistant Cabinet
  • Remote DX Coil Service
Demander un devis. Browse les produits

Introduction de produit

The air-cooled condensing unit combines scroll compressors, a finned outdoor condenser, axial fans, refrigerant controls and electrical protection in one weather-resistant enclosure. It connects to a remote evaporator coil in an air-handling unit, keeping compressor noise and rejected heat outside the controlled area. Independent refrigerant circuits and staged fan control can follow varying sensible and latent loads while accessible service panels simplify routine inspection.

Key Features

Microchannel or copper-tube condenser surfaces provide a large outdoor heat-rejection area without cooling-water infrastructure.

Tandem scroll circuits allow capacity steps and retain partial cooling when one circuit is isolated.

Separate liquid and suction service connections support remote AHU evaporators and properly routed field piping.

Removable coil guards and hinged control access keep fans, compressors and electrical components serviceable from the perimeter.

Préoccupations du client produit

Outdoor condensers must reject a variable cleanroom load without introducing cooling water or compromising refrigeration reliability.

A mechanical room has no condenser-water loop or cooling-tower connection.Axial fans move ambient air across the condenser coil, eliminating condenser-water pumps and treatment equipment.
A single compressor cycle creates unstable supply-air temperature at low load.Multiple scroll stages and fan steps provide smaller capacity increments for steadier remote-coil control.
Long refrigerant runs can cause oil-return and pressure-drop problems.Properly sized suction and liquid connections, receivers and service valves support engineered remote-evaporator piping.
Outdoor coil fouling raises head pressure and power demand.Full-face coil guards and perimeter access allow inspection and cleaning without dismantling the cabinet.

Les applications typiques

Pharmaceutical cleanroom air-handling systemsElectronics manufacturing make-up air unitsLaboratory dedicated outdoor-air systemsMedical-device production HVACRemote DX process-cooling air handlers

Paramètres techniques

Representative commercial construction ranges for an outdoor cleanroom condensing unit are listed below.

Matériaux de basePowder-coated galvanized steel enclosure with copper-tube/aluminum-fin or all-aluminum microchannel condenser coil
Panneau épaisseur1.0-1.5 mm removable cabinet panel thickness
Largeur effective900-2200 mm nominal cabinet width
Longueur maximaleUp to 4200 mm for multi-compressor assemblies
Acier face épaisseur1.0-1.5 mm galvanized steel exterior panels
Densité CoreApproximately 2660-2840 kg/m³ for the aluminum condenser fins or microchannel heat-exchanger sections
Conductivité thermiqueApproximately 113-234 W/(m·K) for the aluminum condenser heat-transfer material
surface finieUV-resistant polyester powder coating over galvanized steel
Type jointBolted modular casing with gasketed service panels and brazed refrigerant joints
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Single, tandem or multiple scroll-compressor circuitsCopper-tube/aluminum-fin or microchannel condenser coilLow-ambient fan control and condenser-coil guardsRemote monitoring contacts and variable-speed condenser fans

Planning a Air-Cooled Condensing Unit specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact