Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Reinraum HVAC und Luftbehandlung Ausrüstung

Luftgekühlte Kondensationseinheit

A factory-assembled outdoor refrigeration unit that rejects cleanroom cooling loads directly to ambient air and supplies liquid refrigerant to a remote DX coil.
  • Direct Ambient Heat Rejection
  • Staged Scroll Compression
  • Weather-Resistant Cabinet
  • Remote DX Coil Service

Produkteinführung

The air-cooled condensing unit combines scroll compressors, a finned outdoor condenser, axial fans, refrigerant controls and electrical protection in one weather-resistant enclosure. It connects to a remote evaporator coil in an air-handling unit, keeping compressor noise and rejected heat outside the controlled area. Independent refrigerant circuits and staged fan control can follow varying sensible and latent loads while accessible service panels simplify routine inspection.

Key Features

Microchannel or copper-tube condenser surfaces provide a large outdoor heat-rejection area without cooling-water infrastructure.

Tandem scroll circuits allow capacity steps and retain partial cooling when one circuit is isolated.

Separate liquid and suction service connections support remote AHU evaporators and properly routed field piping.

Removable coil guards and hinged control access keep fans, compressors and electrical components serviceable from the perimeter.

Kunden Produktbedenken

Outdoor condensers must reject a variable cleanroom load without introducing cooling water or compromising refrigeration reliability.

A mechanical room has no condenser-water loop or cooling-tower connection.Axial fans move ambient air across the condenser coil, eliminating condenser-water pumps and treatment equipment.
A single compressor cycle creates unstable supply-air temperature at low load.Multiple scroll stages and fan steps provide smaller capacity increments for steadier remote-coil control.
Long refrigerant runs can cause oil-return and pressure-drop problems.Properly sized suction and liquid connections, receivers and service valves support engineered remote-evaporator piping.
Outdoor coil fouling raises head pressure and power demand.Full-face coil guards and perimeter access allow inspection and cleaning without dismantling the cabinet.

Typische Anwendungen

Pharmaceutical cleanroom air-handling systemsElectronics manufacturing make-up air unitsLaboratory dedicated outdoor-air systemsMedical-device production HVACRemote DX process-cooling air handlers

Technische Parameter

Representative commercial construction ranges for an outdoor cleanroom condensing unit are listed below.

Core MaterialPowder-coated galvanized steel enclosure with copper-tube/aluminum-fin or all-aluminum microchannel condenser coil
Panel Dicke1.0-1.5 mm removable cabinet panel thickness
Effektive Breite900-2200 mm nominal cabinet width
Maximale LängeUp to 4200 mm for multi-compressor assemblies
Stahl facing Dicke1.0-1.5 mm galvanized steel exterior panels
KerndichteApproximately 2660-2840 kg/m³ for the aluminum condenser fins or microchannel heat-exchanger sections
Thermische LeitfähigkeitApproximately 113-234 W/(m·K) for the aluminum condenser heat-transfer material
Oberfläche FinishUV-resistant polyester powder coating over galvanized steel
Gemeinsamer TypBolted modular casing with gasketed service panels and brazed refrigerant joints
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Single, tandem or multiple scroll-compressor circuitsCopper-tube/aluminum-fin or microchannel condenser coilLow-ambient fan control and condenser-coil guardsRemote monitoring contacts and variable-speed condenser fans