Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / Reinraumtüren, Fenster und Interlock-Systeme / Three-Door Cleanroom Interlock System
Reinraumtüren, Fenster und Interlock-Systeme

Drei-Tür Reinraum Interlock System

A three-channel airlock control package for vestibules with one common entrance and two controlled exits, or other cleanroom routes requiring defined three-door sequencing.
  • Three Independent Door Channels
  • Branching Airlock Logic
  • Configurable Door Groups
  • Individual Status Indication

Produkteinführung

The three-door interlock system extends standard airlock logic to a branching layout. Each door has its own closed-position input, release output and request/status station, while the controller defines which combinations must remain mutually exclusive. This supports a common entry serving two process rooms, a personnel-and-material branch, or a three-sided transfer vestibule. Channel-specific indication helps occupants identify which route is available rather than treating every locked condition as the same fault.

Key Features

Three independent sensor and lock channels support one common door and two destination doors.

Programmable grouping permits all-door mutual exclusion or selected route combinations.

Individual status outputs identify the requested door and the channel currently blocking release.

Separate held-open timers reveal which of the three doors has exceeded its permitted opening time.

Kunden Produktbedenken

Three-door layouts require unambiguous route logic because a simple pairwise interlock can create unintended releases or lock every exit unnecessarily.

A common entrance serves two clean rooms with different access paths.Three discrete channels apply the release rule to the selected branch instead of wiring separate controllers independently.
Users cannot tell which of two destination doors is available.Door-specific request and status indication shows each branch state locally.
Independent two-door relays create conflicting logic around the shared door.One controller evaluates all three door contacts before issuing any lock release.

Typische Anwendungen

Branching personnel airlocksThree-sided material vestibulesShared gowning-room exitsLaboratory corridor transfer nodes

Technische Parameter

Typical construction and interface ranges for a three-door cleanroom interlock system are listed below.

Core MaterialThree-channel programmable controller, power supply, relays, door contacts and operator stations
Panel Dicke90–150 mm controller enclosure depth
Effektive Breite240–320 mm controller enclosure width
Maximale Länge400 mm controller enclosure height
Stahl facing Dicke1.0–1.5 mm steel cabinet; stainless operator plates typically 1.2–2.0 mm
KerndichteApproximately 1800–1920 kg/m³ for the three-channel glass-reinforced PCB laminate
Thermische LeitfähigkeitApproximately 0.4–0.7 W/(m·K) for the channel-control PCB laminate
Oberfläche FinishPowder-coated control enclosure with labeled terminals and cleanroom-compatible operator stations
Gemeinsamer TypThree hardwired door channels with configurable grouping, common emergency input and auxiliary dry contacts
CustomisierungVerfügbar basierend auf der beabsichtigten Anwendung und Betriebsumgebung

Verfügbare Optionen

All-door or branch-specific exclusion logicThree touchless request stationsIndependent door-held alarmsAccess-control and BMS status contacts

Planning a Three-Door Cleanroom Interlock System specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns