A flush brushed-stainless wall port that provides a capped connection point for cleanroom differential-pressure verification and reference tubing.
  • Flush Stainless Wall Plate
  • Capped M5 Test Nipple
  • Two-Screw Mounting Pattern
  • Rear Pressure-Tube Connection
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The room pressure test port uses a slim rectangular stainless faceplate to bring a low-pressure reference line to an accessible cleanroom wall surface. A central threaded service nipple accepts a compatible portable manometer hose, while the rear fitting connects to the concealed pressure tube. The knurled closure stays attached to a dedicated chain anchor and seals the exposed test point between checks. Two vertically aligned mounting holes and a compressible backing gasket keep the plate stable and limit false readings caused by air movement from the wall cavity.

Các tính năng chính

The low-profile brushed plate presents a smooth wipeable surface at the monitored room boundary.

A central M5 service nipple gives technicians a defined connection for compatible differential-pressure test tubing.

The knurled sealing cap closes the pressure opening between measurements and remains captured by a short stainless chain.

Two countersunk holes on the vertical centerline secure the plate without crowding the pressure fitting.

A single rear bulkhead connector provides a direct transition to the concealed reference tube without an exposed instrument body.

Các mối quan tâm về sản phẩm của khách hàng

Very small room pressure differences are easily distorted by wall-cavity drafts, contaminated tubing or an unsealed service connection.

Air leaking around a loose wall plate can bias the pressure reference at the pickup point.The two-screw faceplate compresses a compatible backing gasket against the finished wall surface.
An open test nipple can collect cleaning residue or become a persistent pressure leak.The close-fitting knurled cap seals the front connection and stays attached to its dedicated chain anchor.
Long, kinked or wet reference tubing slows response and produces unstable manometer readings.The direct rear fitting supports a short, correctly routed tube that can be inspected for blockage and condensation.
A service fitting mounted without anti-rotation support can loosen when test hoses are connected repeatedly.The rectangular plate and separated top-and-bottom fixings resist turning loads around the central nipple.

Các ứng dụng điển hình

Portable verification of cleanroom-to-corridor pressure differenceReference pressure pickup at isolation and protection roomsCommissioning checks for cleanroom pressure cascadesService access for remote differential-pressure transmitter tubingRoutine maintenance checks in laboratories and controlled production suites

Thông số kỹ thuật

Typical construction and dimensional ranges for a stainless cleanroom wall pressure test port are listed below.

Vật liệu lõi316L stainless-steel faceplate, pressure nipple, cap and chain with a stainless or nickel-plated rear tube fitting
Độ dày bảng điều khiển25-120 mm compatible modular wall or ceiling panel thickness
Chiều rộng hiệu quảApproximately 70 mm nominal single-gang faceplate width
Chiều dài tối đaUp to 120 mm overall faceplate length
Thép đối mặt với độ dày1.0-1.5 mm nominal stainless faceplate thickness
Mật độ lõiApproximately 7900-8000 kg/m³ for austenitic stainless-steel components
Độ dẫn nhiệtKhoảng 14-16 W / (m·K) cho thép không gỉ 316L
Kết thúc bề mặtFine-brushed and passivated natural stainless steel with smooth radiused plate edges
Loại khớp nốiTwo-screw gasketed wall plate with central M5 front test nipple and coaxial rear pressure-tube connection
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

304 or 316L stainless-steel plate and hardwareAlternative front test-thread and hose-adapter sizesBarbed or positive-lock rear tubing connectionPanel-depth gland extension for thicker cleanroom wallsEPDM or silicone backing gasket and custom fixing-hole spacing