Sistema de control DDC para sala limpia por

A distributed direct-digital-control panel that manages cleanroom HVAC loops, schedules and alarms through networked BACnet room and plant controllers.
  • Distributed HVAC Control
  • BACnet Controller Network
  • Local Trend Buffering
  • Expandable Universal I/O
Solicite un presupuesto. Browse productos

Introducción del producto

DDC controllers are distributed between AHUs, mechanical rooms and cleanroom zones so each group of HVAC points is controlled close to the equipment. Universal inputs accept common temperature, humidity and pressure signals, while analog and digital outputs command dampers, valves and fan drives. BACnet communication exposes live values, alarms, schedules and trends to the building-management platform. Local programs and retained configuration allow the controlled plant to continue operating during a supervisory-network interruption.

Características clave

Distributed controllers shorten field wiring between HVAC equipment and the control point.

Universal I/O channels can be configured for common sensor, contact and actuator signals.

Local schedules, alarms and trend buffers remain active without a central workstation connection.

BACnet networking supports shared values and coordinated operation across multiple cleanroom zones.

Preocupaciones del producto del cliente

A DDC system must distribute control efficiently while preserving a consistent point structure and dependable communication to the central BMS.

Long home-run cables increase installation complexity and analog noise.Local DDC panels position I/O near AHUs and cleanroom zone equipment.
Different controller programs use inconsistent point names.A standardized device and point naming structure keeps graphics, alarms and trends aligned.
Supervisory network loss interrupts basic plant sequences.Local DDC logic, schedules and retained setpoints continue at the controller level.
Adding one sensor consumes a dedicated fixed-function module.Configurable universal I/O channels accommodate several common signal types.

Aplicaciones típicas

Air-handling unit DDCCleanroom zone controlMechanical-room automationBuilding automation retrofits

Parámetros técnicos

Typical cleanroom DDC panel construction ranges are given below.

Materiales CorePowder-coated steel enclosure with FR-4 DDC boards and pluggable copper terminals
Panel de espesor160-300 mm enclosure depth
Ancho efectivo400-800 mm panel width
Longitud máximaUp to 1200 mm panel height
Acero frente a espesor1.2-1.5 mm powder-coated steel panels
Densidad Core7800-8050 kg/m³ for steel enclosure components
Conductividad térmica45-60 W/(m·K) for the steel cabinet
Superficie acabadaFine-textured off-white powder coat with printed terminal identification
Tipo conjuntoWall-mounted DIN-rail enclosure with removable terminal blocks and BACnet trunk connections
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

BACnet MS/TP or BACnet/IPLocal operator displayRemote I/O expansionIntegrated 24 VAC power supply