Ventilador centrífugo curvo hacia atrás
- Stable Backward-Curved Wheel
- Non-Overloading Power Characteristic
- Rigid Welded Scroll Casing
- Adjustable Belt-Drive Base
Introducción del producto
The backward-curved centrifugal fan draws air axially through a streamlined inlet cone, turns it through the rotating wheel and converts velocity into static pressure inside a spiral casing. Backward-inclined blades provide a broad stable operating region and reduce the risk of motor overload when system resistance changes. The fan assembly combines a fabricated steel scroll, dynamically balanced wheel, external bearings, motor slide base and vibration-isolated frame for service in cleanroom HVAC plant areas.
Características clave
A close-clearance inlet cone guides air into the wheel eye with reduced turbulence and entrance loss.
External pillow-block bearings and a guarded belt drive remain accessible without entering the fan casing.
A welded structural base preserves shaft alignment while allowing the motor position to be adjusted for belt tension.
Preocupaciones del producto del cliente
Central HVAC systems need a fan that can maintain useful pressure as filters load and dampers move, without exposing the motor to an uncontrolled power increase.
Aplicaciones típicas
Parámetros técnicos
Representative construction ranges for a belt-driven backward-curved centrifugal fan used in clean HVAC service are listed below.
| Materiales Core | Fabricated galvanized or epoxy-coated carbon-steel scroll with a welded backward-curved steel wheel and structural base |
|---|---|
| Panel de espesor | 2.0-4.0 mm typical scroll side-plate and wrap thickness |
| Ancho efectivo | 700-2600 mm nominal fan assembly width according to wheel size |
| Longitud máxima | Up to 4500 mm overall length including motor slide base and drive guard |
| Acero frente a espesor | 2.0-5.0 mm carbon-steel casing, inlet cone and reinforcement sheet |
| Densidad Core | Approximately 7800-7900 kg/m³ for the carbon-steel wheel and casing |
| Conductividad térmica | Approximately 45-55 W/(m·K) for carbon-steel structural components |
| Superficie acabada | Zinc-rich primer with blue epoxy topcoat on the base and corrosion-resistant coating on exposed steel |
| Tipo conjunto | Welded spiral scroll with bolted inlet and discharge flanges, keyed shaft and belt-driven motor connection |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Backward-Curved Centrifugal Fan specification?