Unit Penapis Kipas Berdiri Lantai

A self-supporting filtered-air station that places an FFU at process height on a rigid floor frame for localized horizontal clean-air coverage.
  • Self-Supporting Frame
  • Process-Height Air Delivery
  • Adjustable Levelling Feet
  • Single or Twin FFU Layout
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The floor-standing fan filter unit mounts one or two standard filter modules in a reinforced steel frame rather than in a suspended ceiling. Its fixed-height legs carry the fan mass and align the discharge face with the work surface, while wide levelling pads compensate for uneven floors. Power and speed controls are routed along the rear uprights to keep the clean-air face clear. This arrangement establishes a local horizontal clean zone beside production machinery, transfer openings or benchtop operations without modifying the building ceiling system.

Ciri-ciri Utama

A rigid rectangular base carries the complete FFU load independently of ceiling panels or wall framing.

The elevated module aligns filtered discharge with benches, conveyors and equipment access openings.

Rear cable routing keeps electrical leads away from the clean airflow and operator path.

Single- and twin-module frames permit the protected width to be matched to the process footprint.

Kebimbangan Produk Pelanggan

A fixed clean-air source is often needed beside existing equipment where neither ceiling reconstruction nor constant relocation is desirable.

Retrofitting a ceiling grid for one local process causes disproportionate shutdown and construction work.The self-supporting floor frame adds filtered airflow without opening the overhead envelope.
A low temporary purifier directs clean air below the actual handling surface.The raised FFU face is positioned at the working elevation for useful horizontal coverage.
Uneven floors cause a tall clean-air wall to lean and misdirect the airflow plane.Four adjustable levelling feet establish a stable vertical frame and repeatable outlet alignment.
Power cables crossing the front of the unit obstruct cleaning and material movement.Rear uprights conceal protected cable routes and keep the discharge side uncluttered.

Permohonan yang biasa

Temporary clean production cellsEquipment loading interfacesBenchtop assembly protectionPackaging and inspection stationsCleanroom retrofit areas

Parameter teknikal

Typical dimensional and material ranges for a fixed floor-standing FFU station are provided below.

Bahan TerasPowder-coated steel support frame with EC fan module and micro-glass HEPA or ULPA filter
Ketebalan Panel380-600 mm overall frame and FFU depth
Lebar berkesan610-2440 mm clean-air face width for one or two modules
Panjang maksimumUp to 2100 mm overall standing height
Keluli Menghadapi Ketebalan1.2-2.0 mm folded steel frame; 0.8-1.2 mm FFU enclosure
Ketumpatan terasApproximately 90-120 kg/m³ compacted density of the HEPA or ULPA pack installed in the floor-standing cabinet
Kekonduksian TermaApproximately 0.035-0.043 W/(m·K) for the dry final-filter pack in the floor-standing FFU
Kemasan permukaanWhite powder-coated frame with blue control box and stainless or anodized diffuser
Jenis BersatuBolted modular frame with compression-seal filter and adjustable threaded floor feet
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

One- or two-FFU support frameFixed feet or floor anchorsHorizontal positive-flow or reverse-flow arrangementIntegrated speed controller and differential-pressure display