상품 소개
The junction box sits inside the cleanroom wall panel and presents only a flat stainless access cover to the room. A continuous gasket seals the cover to the recessed frame and countersunk captive screws distribute compression around the edge. Internal DIN rail, terminals and cable glands organize branch wiring while remaining outside the primary cleaning surface.
주요 기능
Captive screws remain attached during electrical access.
A continuous seal prevents the wall cavity from opening into the room.
Internal earth studs and terminal rail provide an organized bonding point.
Rear and side gland plates route cables without field-cut openings in the face.
고객 제품 관심사
Electrical splices require future access, but a removable panel can compromise wall integrity if its cover and cable routes are not sealed.
A surface junction box creates a large top ledge.The enclosure recesses fully behind a flush access plate.
Loose cover screws fall into the controlled room.Captive countersunk fasteners remain retained in the plate.
Unsealed cable holes connect the room to the wall cavity.Matched glands close each conductor route inside the back box.
Mixed splices make troubleshooting slow and error prone.Labeled DIN terminals and earth studs organize each circuit.
일반적인 응용 프로그램
Cleanroom lighting branchesInstrumentation splicesAccess-control wiringWall-panel service distribution
기술 매개변수
Typical configurable construction ranges for a flush-mounted junction box are listed below.
| 핵심 재료 | SUS304 or SUS316L cover and frame with galvanized or stainless recessed box, DIN rail and terminal blocks |
|---|---|
| 패널 두께 | 1.5-3.0 mm flush access-cover thickness |
| 유효 폭 | 150-600 mm clear internal box width |
| 최대 길이 | Up to 800 mm overall recessed enclosure height |
| 강철 면면 두께 | 1.5-2.0 mm cover; 1.0-1.5 mm recessed box |
| 코어 밀도 | Approximately 7900-8000 kg/m³ for the stainless cover and frame |
| 열전도도 (Thermal Conductivity) | 14-16 W/(m·K) for the stainless access plate |
| 표면 마무리 | Fine-brushed or electropolished flush stainless cover with engraved circuit reference |
| 접합 유형 | Gasketed recessed frame with captive countersunk cover screws and gland-sealed rear entries |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |