クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルームユーティリティシステム

VOC 排気処理ユニット

Compact skid-mounted flameless regenerative thermal oxidation unit that treats compatible low- to medium-concentration VOC exhaust through an insulated ceramic heat-exchange bed with controlled electric or gas support energy.
  • Flameless oxidation within a regenerative ceramic bed
  • Compact modular skid with integrated fan and PLC controls
  • High internal heat recovery reduces support-energy demand
見積もりリクエスト 製品案内

商品紹介

The VOC Exhaust Treatment Unit is a compact regenerative thermal oxidizer for compatible organic-vapor exhaust from coating, printing, electronics, pharmaceutical and clean-manufacturing processes. Contaminated air is drawn through a regenerative media bed, heated to the selected oxidation condition and held long enough for the organic load to be converted primarily to carbon dioxide and water. Alternating flow through the media recovers much of the sensible heat before clean exhaust leaves the unit. The displayed configuration combines one insulated oxidation module, one process fan, one inlet isolation damper, one electric support-heater section, one PLC cabinet and a common base. Exhaust composition, concentration, particulate loading, halogens, oxygen content, flow turndown and heat recovery are evaluated before selecting the treatment arrangement.

主要な特徴

A single insulated regenerative bed combines oxidation and heat recovery in a compact vertical module

Flameless operation avoids a conventional open burner inside the oxidation zone

Ceramic media stores and returns process heat as the airflow direction alternates

A dedicated process fan maintains the required exhaust movement through the treatment train

PLC sequencing coordinates warm-up, damper movement, operating temperature and controlled shutdown

Differential-pressure and temperature points provide practical indication of bed loading and thermal condition

An inlet isolation damper separates the process duct during maintenance or a defined trip

Modular casing and removable service panels provide access to the fan, heater, valves and media sections

Electric or compatible fuel support energy can be selected for the available site utility

Secondary heat-recovery connections can be evaluated when useful recovered energy has a stable destination

お客様の製品に関する懸念事項

VOC abatement performance depends on the real exhaust chemistry and operating envelope. Concentration, oxygen, particulates, corrosive species, flow variation and heat release must be understood before an oxidation system is selected.

Large swings in VOC concentration can move the oxidizer between support-energy demand and excessive heat releaseCharacterize normal, startup and upset loading, then apply suitable dilution, bypass, heat-removal and control limits for the selected stream.
Particulate, condensable aerosol or resin can foul the ceramic bed and raise pressure dropProvide compatible upstream separation and keep the duct and treatment train above problematic condensation conditions where required.
Halogenated, sulfur-bearing or silicon-containing compounds can create corrosive products or persistent depositsReview every expected constituent and add compatible metallurgy, downstream neutralization or another treatment technology when oxidation alone is unsuitable.
A process may be sensitive to pressure changes when the flow direction switchesSize the fan, switching valve and control sequence around the permitted process pressure fluctuation and verify it through the full operating range.
Insufficient warm-up or an uncontrolled shutdown can leave untreated exhaust or damage internal componentsInterlock process admission with verified thermal conditions and use a defined purge, cooldown and emergency-isolation sequence.
A nominal destruction figure may not represent the installed exhaust mixture or required legal test basisDefine the target compounds, operating envelope, sampling locations and acceptance method before selecting and evaluating the final system.

典型的な用途

Semiconductor, display and electronics process exhaust containing compatible organic vaporsPharmaceutical coating, solvent-handling and formulation exhaustPrinting, laminating and surface-coating lines with dilute VOC streamsBattery, composite and advanced-material manufacturing exhaustOdor-bearing industrial air streams where thermal oxidation is technically suitableCentral treatment of several balanced low- to medium-concentration VOC sources

技術的なパラメータ

The displayed basis is one compact skid-mounted flameless regenerative thermal oxidation module with an insulated carbon-steel casing, a 96 kg/m³ high-temperature fiber lining, ceramic heat-exchange media, one direct-coupled process fan, one electric support-heater section and one side-mounted PLC cabinet. The site's fixed ten-row table uses panel-oriented labels; here the dimensional rows describe the displayed insulated module rather than a universal oxidizer size. Final airflow, residence condition, heat release, utility load, metallurgy, switching arrangement and pressure control remain application-selected.

コア材料Insulated carbon-steel process casing with regenerative ceramic media, 96 kg/m³ high-temperature fiber lining, stainless hot-face retainers and separate fan and control modules
パネルの厚さ50-100 mm representative high-temperature lining build-up for the displayed modular casing
有効幅Approximately 2200 mm displayed skid width including oxidation module, fan and side control cabinet
最大長さApproximately 4500 mm displayed skid length including inlet section and maintenance clearance envelope
鋼鉄の厚さを直面する3-6 mm representative welded carbon-steel outer casing, with hot-zone reinforcement selected for temperature and pressure
コア密度96 kg/m³ representative density for the selected high-temperature fiber insulation layer
熱伝導率Approximately 0.12 W/(m·K) at a 538°C mean temperature for a representative 128 kg/m³ ceramic-fiber blanket; final lining grade is selected separately
表面仕上げLight-gray industrial coating on cool external steel, dark stainless hot-zone trim, natural-silver ductwork and restrained safety-color handles and indicators
ジョイントタイプWelded and bolted insulated module joints with flanged process-duct connections, gasketed service doors and wired PLC and instrument interfaces
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Single, twin or multiple modular treatment trains for the required exhaust flowElectric, natural-gas or other compatible support-energy arrangementsAlternative ceramic-media geometries for pressure-drop and thermal-recovery targetsUpstream particulate, aerosol or condensate pretreatmentCorrosion-resistant hot-face alloys for compatible challenging exhaust chemistryProcess bypass, dilution-air and high-temperature heat-removal configurationsSecondary heat recovery to air, water, thermal oil or steam serviceRemote HMI, historian and plant-network communication interfacesDifferential-pressure, LEL, oxygen and expanded temperature monitoringIndoor or weather-protected outdoor modular enclosure packages

Planning a VOC Exhaust Treatment Unit specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ