クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
FFU およびターミナル空気浄化装置

クリーンルーム HEPA ターミナルハウジング

A fanless welded ceiling filter box that connects the supply duct to a sealed HEPA or ULPA panel and cleanroom diffuser with room-side service access.
  • Fully Welded Fanless Housing
  • Top or Side Duct Collar
  • Gel-Seal Filter Option
  • Interchangeable Diffuser Face
見積もりリクエスト 製品案内

商品紹介

The cleanroom HEPA terminal housing forms the final sealed transition between a central air-supply duct and the cleanroom. Its fully welded steel plenum accepts a top or side collar, while an internal clamping frame holds a HEPA or ULPA panel against a gasket or gel knife edge. A hinged or quick-release room-side diffuser provides access to the filter, pressure port and upstream challenge connection. Because the module contains no fan, airflow is governed by the upstream air-handling system and an optional inlet damper, making it well suited to ducted pharmaceutical, laboratory and healthcare ceilings.

主要な特徴

Fully welded plenum seams create a continuous pressure boundary between the duct collar and filter seat.

Top, side-round or side-rectangular inlet positions accommodate different ceiling-clearance conditions.

Room-side clamps retain the filter evenly and allow replacement without removing the terminal box.

Interchangeable perforated, swirl or adjustable-nozzle faces adapt the discharge pattern to the room layout.

お客様の製品に関する懸念事項

A terminal filter box must prevent bypass leakage, fit restricted ceiling space and remain serviceable without disturbing the supply duct.

Folded or spot-welded plenum seams can leak unfiltered supply air around the final filter.Continuous welded seams maintain a sealed pressure path from the duct inlet to the filter seat.
A centred top collar conflicts with structural members or shallow ceiling services.Alternative top, side-round and side-rectangular connections allow the plenum to fit the available space.
Uneven filter clamping leaves local gaps around a gasket or gel channel.Multiple room-side retaining points apply balanced compression around the complete frame.
One fixed diffuser pattern causes draughts or poor room mixing after a layout change.Replaceable front plates provide perforated vertical, swirl or adjustable radial discharge patterns.

典型的な用途

製薬クリーンルームの天井Hospital isolation and procedure roomsBiotechnology laboratoriesFood and beverage controlled areasDucted microelectronics clean zones

技術的なパラメータ

Typical material and size ranges for a ducted cleanroom HEPA terminal housing are listed below.

コア材料Fanless welded steel plenum with aluminium-frame micro-glass HEPA or ULPA mini-pleat filter
パネルの厚さ250-500 mm housing depth excluding duct collar
有効幅305-1220 mm nominal filter and diffuser width
最大長さUp to 1220 mm standard terminal housing length
鋼鉄の厚さを直面する1.0-1.5 mm fully welded powder-coated or stainless-steel plenum
コア密度Approximately 90-120 kg/m³ compacted density of the HEPA or ULPA pack seated in the terminal housing
熱伝導率Approximately 0.035-0.043 W/(m·K) for the final-filter pack seated in the cleanroom terminal housing
表面仕上げWhite epoxy-polyester powder coat or brushed 304 stainless steel
ジョイントタイプWelded duct plenum with room-side compression gasket or knife-edge gel-seal filter clamp
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Top-round, side-round or side-rectangular inletHEPA H13-H14 or ULPA filterPerforated, swirl or adjustable-nozzle diffuserRoom-side pressure and aerosol test ports

Planning a Cleanroom HEPA Terminal Housing specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ