refroidissement à eau
- Stable Indoor Operation
- High Heat-Exchanger Efficiency
- Screw or Centrifugal Compression
- Cooling-Water Heat Rejection
Introduction de produit
The water-cooled chiller uses a refrigerant evaporator to cool the cleanroom chilled-water loop and a separate condenser to transfer heat into cooling-tower or process water. Because condensing temperature is controlled by water rather than hot roof air, the unit can achieve stable performance and compact indoor placement at large capacity. Screw compressors provide robust staged or variable capacity, while centrifugal machines suit still larger duty. Water flow, fouling allowance and treatment are coordinated for both heat exchangers.
Key Features
Shell-and-tube heat exchangers provide serviceable water circuits for medium and large plant capacities.
Variable compressor capacity follows cleanroom load without relying only on compressor cycling.
Indoor installation protects refrigeration equipment from outdoor weather and airborne debris.
Préoccupations du client produit
A water-cooled chiller depends on both the chilled-water and condenser-water systems; poor flow or fouling on either side reduces plant performance.
Les applications typiques
Paramètres techniques
Typical construction and evaporator insulation data for an indoor water-cooled chiller are shown below.
| Matériaux de base | Closed-cell elastomeric sheet on the evaporator, waterboxes and suction elbow |
|---|---|
| Panneau épaisseur | 1.0–2.0 mm removable compressor and control enclosure panels |
| Largeur effective | 1200–3000 mm nominal equipment width |
| Longueur maximale | Up to 8000 mm including compressor and shell-and-tube exchangers |
| Acier face épaisseur | 1.0–2.5 mm enclosure sheet with heavier welded base steel |
| Densité Core | 52.5 kg/m³ nominal closed-cell elastomeric insulation |
| Conductivité thermique | 0.033 W/(m·K) at 0°C for the evaporator insulation |
| surface finie | Powder-coated structural steel and removable panels with insulated cold-surface piping |
| Type joint | Welded skid base with bolted compressor enclosure and flanged or grooved water connections |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Water-Cooled Chiller specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien