Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Équipement d'écoulement et de confinement laminaires

Testeur d'intégrité de gant isolant par

A portable pressure-decay test head that seals inside an isolator glove port, inflates the glove and measures pressure loss without removing the sleeve assembly.
  • In-Situ Pressure-Decay Test
  • Inflatable Port Seal
  • Wireless Portable Test Head
  • Multiple Port Adapter Options
Demander un devis. Browse les produits

Introduction de produit

The glove integrity tester attaches to the isolator or RABS glove ring from inside the chamber. An inflatable circumferential seal fixes the lightweight test head in the port, then the instrument fills the glove and sleeve to the selected test pressure and records the decay over time. Battery power and wireless communication reduce hoses and cables across the barrier. Adapter sizes, test pressure and acceptance settings are matched to the actual glove material and port geometry.

Key Features

An inflatable seal centers the test head without mechanical tools.

Pressure-decay measurement checks the glove and sleeve while installed in the port.

Battery power removes an external pneumatic hose from the chamber.

Wireless control can manage one or several test heads from a tablet or workstation.

Interchangeable adapters support different glove-ring diameters.

Préoccupations du client produit

Gloves are flexible barrier components that must be checked in their installed condition without creating a new leak around the test connection.

A rigid test plug damages or misaligns the glove ring.A lightweight head with an inflatable seal adapts to the port circumference.
External hoses obstruct adjacent glove positions.Battery power and wireless control keep the installed test head self-contained.
Different glove materials behave differently under pressure.Test pressure, stabilization and measurement time are configured for each glove type.
One adapter does not fit all barrier systems.Interchangeable port adapters cover the selected glove-ring dimensions.

Les applications typiques

Aseptic isolator glove checksContainment isolator maintenanceRABS glove managementRoutine barrier inspection

Paramètres techniques

Typical configurable construction ranges for an isolator glove integrity tester are listed below.

Matériaux de baseAnodized aluminum or SUS316L test head with engineering-polymer housing and inflatable silicone sealing ring
Panneau épaisseur3-8 mm instrument housing and adapter wall sections
Largeur effective200-400 mm compatible glove-port diameter
Longueur maximaleUp to 450 mm overall portable test-head length
Acier face épaisseur1.5-3.0 mm SUS316L adapter and protective components
Densité Core1150-1300 kg/m³ for engineering-polymer housing components
Conductivité thermique0.20-0.35 W/(m·K) for the engineering-polymer housing
surface finieSmooth cleanroom-compatible polymer with anodized or electropolished metal adapters
Type jointTool-free inflatable circumferential port seal with interchangeable adapter ring and integrated pressure connection
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Standalone or integrated controllerSingle-head or multi-head charging trolleyPort-specific adapter setsWireless data and report interface

Planning a Isolator Glove Integrity Tester specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact