Unité de traitement de l'air frais

A supply-only air handler that filters and conditions 100% outdoor air before it enters the cleanroom recirculation or supply system.
  • 100% Outdoor Air Treatment
  • Deep Cooling and Reheat
  • Intake Filter Protection
  • Cleanroom Pressurization Support
Demander un devis. Browse les produits

Introduction de produit

A fresh air handling unit treats the full outdoor-air load required for ventilation, process exhaust replacement and building pressurization. Its treatment train normally includes weather intake protection, staged filtration, cooling and dehumidifying coils, reheat and optional humidification. Because outdoor conditions vary widely, coils and valves are selected for peak latent as well as sensible duty. The supply fan modulates to the scheduled ventilation quantity while frost protection and drainable wet sections protect the unit during seasonal operation.

Key Features

The unit processes 100% outdoor air without recirculating contaminants from occupied or process spaces.

Deep cooling followed by controlled reheat separates moisture removal from final supply-air temperature.

Intake screens, dampers and prefilters protect coils from weatherborne debris and particulate loading.

Supply-air volume can track facility exhaust or pressure demand through variable-speed fan control.

Préoccupations du client produit

Outdoor air imposes the widest temperature, moisture and contamination range on a cleanroom HVAC system.

Humid summer air raises cleanroom dew point even when room temperature is acceptable.A deep cooling coil removes latent moisture before reheat establishes the required supply temperature.
Exhaust systems pull the cleanroom negative during high process operation.Fan airflow tracks the measured replacement-air or pressure requirement.
Wind-driven rain reaches filters and shortens their service life.A weather louver, drainage section and staged prefiltration protect internal treatment components.
Cold outdoor air freezes the first water coil during low-flow operation.Low-temperature detection, preheat and coordinated damper/fan control protect the coil circuit.

Les applications typiques

Cleanroom ventilation-air supplyLaboratory exhaust-air replacementPharmaceutical pressure make-upHospital outside-air treatmentBattery and electronics facilities

Paramètres techniques

Typical casing construction for a cleanroom fresh-air handling unit is summarized below.

Matériaux de baseClosed-cell polyurethane insulation in weather-resistant double-skin panels
Panneau épaisseur50–70 mm insulated casing
Largeur effective900–3200 mm nominal unit width
Longueur maximaleUp to 10000 mm including intake, coil, filter and fan sections
Acier face épaisseur0.6–1.0 mm exterior and 0.8–1.0 mm wet-section lining
Densité Core40–45 kg/m³ closed-cell polyurethane
Conductivité thermique0.022–0.026 W/(m·K) for polyurethane casing insulation
surface finieUV-stable powder-coated outer skin with galvanized or stainless cleanable inner skin
Type jointGasketed thermal-break frame with weather-sealed intake and modular section joints
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Hot-water, steam or electric preheatChilled-water or DX dehumidifying coilHot-water, electric or heat-pump reheatSteam or high-pressure humidification