Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Instruments d'essai et de validation de salle blanche

Système de test de qualité du gaz comprimé

A rugged portable multi-channel test system that combines pressure control, dedicated sample flows and modular sensing for particles, pressure dew point and oil-vapour screening in compressed air and compatible process gases.
  • One case for multiple gas-quality channels.
  • Dedicated pressure and flow control paths.
  • Organized modules for repeatable field setup.
Demander un devis. Browse les produits

Introduction de produit

This integrated field system organizes several compressed-gas purity measurements inside one protective open-case platform. A central digital interface coordinates the selected sensor module and records stabilized results, while the analog pressure gauge, two different-range flowmeters and three color-coded regulators keep the particle, moisture and oil-vapour sample paths visibly separated. Three front sampling ports and short color-matched hoses reduce setup ambiguity at changing utility points. The removable sensor module and fitted storage bay support transport without turning the system into a loose collection of handheld instruments. Individual measurement channels are selected and conditioned for their intended contaminant rather than treating one sensor as a universal air-quality detector.

Key Features

One central digital display consolidates guided channel selection, live values, stabilization trends and stored test sessions.

Separate particle, moisture and oil-vapour sample ports maintain distinct flow and conditioning paths inside the case.

One analog inlet-pressure gauge provides a direct pneumatic check before gas is routed to a sensitive measurement module.

Two different-range variable-area flowmeters make low-flow sensor conditioning and higher-flow particle sampling visually distinguishable.

Three color-coded adjustment knobs correspond to the three sampling circuits and reduce connection errors during field setup.

Rugged open-case construction, a removable sensor module and fitted hose storage protect the complete kit during site-to-site transport.

Préoccupations du client produit

A meaningful compressed-gas quality survey must preserve the different sampling needs of particles, water and oil while documenting pressure, flow, test location and stabilization conditions for every channel.

One sample flow cannot represent particle, moisture and oil-vapour measurement requirements equally well.Route each contaminant channel through its designated port, regulator and flowmeter, then allow the selected sensor path to stabilize before recording a result.
Oil, condensate or dirty fittings can transfer contamination between test locations and bias later readings.Use clean capped hoses for each circuit, inspect the inlet before connection and purge or replace the appropriate sample path after an unexpected high-contamination event.
Pressure changes can alter flow and make consecutive site measurements difficult to compare.Check the analog inlet gauge, adjust the color-coded regulator for the active channel and confirm the appropriate flowmeter position throughout the test interval.
A single combined report can hide the sampling method behind each displayed value.Store the measurement point, gas, pressure, selected channel, stabilization period and sensor-module identity together with each particle, dew-point or oil-vapour result.

Les applications typiques

Compressed-air purity surveys at critical points of usePharmaceutical and biotechnology utility-gas investigationsFood and beverage process-air verificationDryer and filtration train performance assessmentIndustrial nitrogen and compatible inert-gas quality checks

Paramètres techniques

Representative construction for a portable compressed-gas quality test system is listed below; sensor ranges, flow circuits, wetted materials, pressure rating and data functions should be configured for the gas and the required purity assessment.

Matériaux de baseImpact-resistant polypropylene transport case with an anodized-aluminum instrument panel, PC/ABS electronic modules, 316L stainless-steel wetted fittings, borosilicate flow tubes and PTFE or compatible polymer sample hoses
Panneau épaisseurTypically 3.0-5.0 mm for the molded case walls and 2.0-3.0 mm for the internal instrument panel
Largeur effectiveApproximately 450-610 mm across the portable open-case platform
Longueur maximaleApproximately 500-650 mm across the largest complete case dimension with transport fittings stowed
Acier face épaisseurTypically 1.0-1.5 mm for stainless internal guards, sensor brackets and pneumatic shielding
Densité CoreApproximately 900-1050 kg/m³ for the impact-resistant polypropylene case structure
Conductivité thermiqueApproximately 0.15-0.22 W/(m·K) for the polypropylene case structure
surface finieDeep-gray textured case, dark-blue corner protection, light-gray anodized panel, blue digital display, white gauge face, clear flow tubes and blue, transparent and black sample hoses
Type jointThree panel-mounted color-coded sampling ports with stainless compression or quick-connect fittings, dedicated short hoses and a removable keyed sensor-module connection
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Optical particle measurement module with isokinetic sampling accessoryLow-range pressure-dew-point sensor moduleOil-vapour screening module with dedicated clean sample pathAlternative inlet-pressure and flowmeter rangesGas-specific hose, regulator and quick-coupling kitsIntegrated data logger with USB or Ethernet export

Planning a Compressed Gas Quality Test System specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact