Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / FFU und Terminalluftreinigungsanlagen / Positive-Pressure HEPA Air Supply Unit
FFU und Terminalluftreinigungsanlagen

Positiver Druck HEPA Luftversorgungseinheit

A portable duct-ready blower that draws source air through staged filtration and delivers HEPA-filtered air into a room to establish a controlled outward pressure bias.
  • Filtered Supply Air
  • Duct-Ready Positive Flow
  • Variable EC Blower
  • Sealed HEPA Final Stage

Produkteinführung

The positive-pressure HEPA air supply unit is arranged with a protected intake, coarse prefilter, optional molecular stage, EC centrifugal blower and final HEPA cassette. Clean air exits through a sealed round supply collar that can connect to a temporary room, enclosure or clean booth. A variable-speed controller sets the delivered airflow, while a filter pressure gauge indicates increasing resistance. Because the unit adds filtered air rather than exhausting room air, pressure is established only when the served enclosure and relief path are appropriately sized.

Key Features

A sealed discharge collar connects filtered supply air directly to a temporary controlled enclosure.

The final HEPA stage is positioned downstream of the blower to capture particles released inside the unit.

Variable EC drive allows the supply volume to be matched to leakage and relief airflow.

A differential-pressure gauge provides a visible indication of combined filter loading.

Kunden Produktbedenken

A temporary clean enclosure needs controlled filtered make-up air, not merely room-air recirculation, to maintain outward leakage at openings.

A recirculating purifier reduces particles but does not add enough air to create positive pressure.The ducted outlet supplies HEPA-filtered air from outside the served enclosure.
Leakage varies when doors, cable openings or softwall panels move.Variable fan control allows the supply flow to be adjusted to the actual leakage path.
Particles from a fan or internal cabinet surface can enter the protected space.The downstream HEPA cassette filters the complete airflow immediately before discharge.
Operators cannot see when accumulated dust is reducing the delivered airflow.A filter pressure indicator shows the resistance trend across the installed stages.

Typische Anwendungen

Temporary positive-pressure cleanroomsPortable inspection enclosuresClean construction zonesSensitive equipment protectionEmergency clean-air supply

Technische Parameter

Typical construction ranges for a portable positive-pressure HEPA supply unit are shown below.

Core MaterialEC centrifugal blower with prefilter, optional carbon stage and downstream micro-glass H13-H14 HEPA filter
Panel Dicke450-800 mm enclosure depth
Effektive Breite500 - 900 mm Kabinettsbreite
Maximale LängeUp to 1200 mm overall unit height including caster base
Stahl facing Dicke1.0-1.5 mm powder-coated steel or 304 stainless-steel pressure enclosure
KerndichteApproximately 90-120 kg/m³ compacted density of the HEPA pack used in the positive-pressure supply unit
Thermische LeitfähigkeitApproximately 0.035-0.043 W/(m·K) for the HEPA pack used in the positive-pressure air supply path
Oberfläche FinishCleanroom-white powder coat with blue supply collar, stainless handles and non-marking casters
Gemeinsamer TypGasketed filter tracks with clamped access door and sealed round or rectangular clean-air supply flange
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Round or rectangular supply connectionHEPA H13 or H14 final stagePrefilter and carbon configurationsCaster-mounted or stationary base

Planning a Positive-Pressure HEPA Air Supply Unit specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat