Gel-Seal HEPA Filter
- Integral Gel Channel
- Continuous Fluid Seal
- Raum-Side - Ersatz
- Low-Outgassing Gel Option
Produkteinführung
The gel-seal HEPA filter adds a continuous perimeter channel to its extruded-aluminum frame and fills it with non-flowing polyurethane or silicone gel. During installation, the terminal housing's matching knife edge penetrates the gel and creates a fluid barrier around the complete filter perimeter. The mini-pleat microglass pack is separately potted inside the frame, so media sealing and housing sealing remain distinct. Because the gel can conform around minor mating-edge irregularities, this design is widely used in bottom-loading and room-side replaceable cleanroom terminals.
Key Features
The mating housing knife edge displaces gel locally to create a resilient fluid barrier.
Separate polyurethane pack potting protects filtration integrity independently of the external seal.
The room-side replaceable geometry reduces access requirements above sealed cleanroom ceilings.
Kunden Produktbedenken
A cleanroom terminal seal must remain continuous even when the ceiling frame has small dimensional tolerances or the filter is replaced repeatedly.
Typische Anwendungen
Technische Parameter
Typical construction ranges for a mini-pleat gel-seal HEPA filter are shown below.
| Core Material | Water-resistant borosilicate microglass HEPA media formed into hot-melt-spaced mini-pleats |
|---|---|
| Panel Dicke | 90, 100 or 120 mm overall frame depth including gel channel |
| Effektive Breite | 305-610 mm terminal-module width |
| Maximale Länge | Up to 1220 mm panel length |
| Stahl facing Dicke | 0.50-0.70 mm optional perforated stainless-steel downstream faceguard |
| Kerndichte | Approximately 90-150 kg/m³ nominal gel-frame HEPA pack density |
| Thermische Leitfähigkeit | Approximately 0.031-0.038 W/(m·K) for dry borosilicate microglass media |
| Oberfläche Finish | Anodized-aluminum frame with clean white media and clear or blue non-hardening gel |
| Gemeinsamer Typ | Integral perimeter gel channel engaged by the matching knife edge of the terminal housing |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Gel-Seal HEPA Filter specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch