Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Luftfilter und chemische Filtration

Gel-Seal HEPA Filter

A cleanroom HEPA panel with an integral non-hardening gel trough that receives the housing knife edge to form a continuous fluid seal.
  • Integral Gel Channel
  • Continuous Fluid Seal
  • Raum-Side - Ersatz
  • Low-Outgassing Gel Option

Produkteinführung

The gel-seal HEPA filter adds a continuous perimeter channel to its extruded-aluminum frame and fills it with non-flowing polyurethane or silicone gel. During installation, the terminal housing's matching knife edge penetrates the gel and creates a fluid barrier around the complete filter perimeter. The mini-pleat microglass pack is separately potted inside the frame, so media sealing and housing sealing remain distinct. Because the gel can conform around minor mating-edge irregularities, this design is widely used in bottom-loading and room-side replaceable cleanroom terminals.

Key Features

A continuous non-hardening gel trough surrounds all four sides of the filter frame.

The mating housing knife edge displaces gel locally to create a resilient fluid barrier.

Separate polyurethane pack potting protects filtration integrity independently of the external seal.

The room-side replaceable geometry reduces access requirements above sealed cleanroom ceilings.

Kunden Produktbedenken

A cleanroom terminal seal must remain continuous even when the ceiling frame has small dimensional tolerances or the filter is replaced repeatedly.

Small irregularities in a rigid mating surface create bypass around a dry seal.Non-hardening gel conforms around the inserted knife edge and closes localized gaps.
Overtightened clamps distort thin aluminum filter frames.The fluid interface reaches sealing contact with controlled engagement rather than extreme compression.
Repeated room-side replacement tears or permanently crushes conventional foam gaskets.A stable gel channel can re-form around the knife edge after careful filter removal and installation.
Aggressive cleaning chemistry affects an unsuitable seal compound.Polyurethane, silicone or low-outgassing gel is selected to match the terminal environment.

Typische Anwendungen

Pharmaceutical aseptic suitesBiotechnologie CleanroomsHospital operating-room ceilingsRoom-side replaceable HEPA housingsLaminar-flow terminal modules

Technische Parameter

Typical construction ranges for a mini-pleat gel-seal HEPA filter are shown below.

Core MaterialWater-resistant borosilicate microglass HEPA media formed into hot-melt-spaced mini-pleats
Panel Dicke90, 100 or 120 mm overall frame depth including gel channel
Effektive Breite305-610 mm terminal-module width
Maximale LängeUp to 1220 mm panel length
Stahl facing Dicke0.50-0.70 mm optional perforated stainless-steel downstream faceguard
KerndichteApproximately 90-150 kg/m³ nominal gel-frame HEPA pack density
Thermische LeitfähigkeitApproximately 0.031-0.038 W/(m·K) for dry borosilicate microglass media
Oberfläche FinishAnodized-aluminum frame with clean white media and clear or blue non-hardening gel
Gemeinsamer TypIntegral perimeter gel channel engaged by the matching knife edge of the terminal housing
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

H13, H14 or ULPA mediaPolyurethane, silicone or low-outgassing gelUpstream or downstream gel-channel orientationStandard or reverse-gel aluminum extrusion

Planning a Gel-Seal HEPA Filter specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt