A scalable interlock architecture that connects multiple local door modules to coordinate airlocks, controlled corridors and transfer zones from one configurable supervisory system.
  • Distributed Door Modules
  • Scalable Interlock Zones
  • Central Status Supervision
  • Facility-System Interfaces
견적 요청 제품 찾아보기

상품 소개

The networked multi-door system separates local door control from facility-level supervision. Door modules near each airlock collect position, request and lock signals, while a central controller coordinates interlock groups and communicates status to authorized operators. This architecture reduces long individual cable runs and allows zones to be expanded or reconfigured without replacing every field device. It is intended for facilities with several interconnected airlocks rather than a single two- or three-door vestibule.

주요 기능

Distributed modules keep time-critical lock and sensor wiring local to each door group.

Configurable zones define which doors are mutually exclusive without hardwiring every relationship.

Central supervision displays door state, held-open alarms and controller communication faults.

Dry-contact or standard network interfaces exchange selected status with access control, fire alarm, BMS or SCADA systems.

고객 제품 관심사

Large interlock schemes must remain understandable and serviceable as door counts increase, while a network fault must not produce uncontrolled door behavior.

Home-running every sensor and lock to one cabinet creates excessive cable length and difficult fault tracing.Distributed local modules collect each zone's field wiring and send coordinated status over a defined network link.
Adding a new cleanroom changes interlock relationships across several existing doors.Configurable door groups can be revised without rebuilding the complete relay architecture.
Operators cannot identify which distant door is holding an entire route locked.Central status supervision identifies the active, open or faulted channel by door name and zone.
A communication failure could leave the release state ambiguous.Local modules use a defined fail-state and retain essential door logic when supervisory communication is unavailable.

일반적인 응용 프로그램

Large pharmaceutical cleanroom suitesMulti-room laboratory facilitiesHospital sterile departmentsSemiconductor controlled-access networks

기술 매개변수

Representative physical and interface ranges for a distributed multi-door interlock platform are listed below.

핵심 재료Central supervisory controller, distributed door I/O modules, regulated supplies, relays and network interfaces
패널 두께100–200 mm central cabinet depth; 60–120 mm local module depth
유효 폭300–600 mm central cabinet width
최대 길이800 mm central cabinet height
강철 면면 두께1.2–1.5 mm powder-coated steel cabinet; stainless local stations typically 1.2–2.0 mm
코어 밀도Approximately 1800–1920 kg/m³ for the controller and distributed-I/O PCB laminates
열전도도 (Thermal Conductivity)Approximately 0.4–0.7 W/(m·K) for the PCB laminates used in the networked modules
표면 마무리Powder-coated central cabinet, sealed local modules and brushed stainless operator plates
접합 유형Networked distributed I/O with local lock/contact terminals, supervised communications and isolated auxiliary interfaces
사용자 정의사용 대상 어플리케이션 및 운영 환경에 따라 사용 가능

사용 가능한 옵션

Four-door to facility-wide channel countsEthernet or fieldbus communicationTouchscreen or web-based status displayAccess-control, fire-alarm, BMS and SCADA integration