/ 제품 / 클린룸 HVAC 및 공기 처리 장비 / Explosion-Proof Axial Exhaust Fan
클린룸 HVAC 및 공기 처리 장비

폭발 방지 축형 배기 팬

A heavy-duty tubular axial fan configured as a complete hazardous-area ventilation assembly, with matched motor protection, material pairing, grounding and cable-entry protection selected for the intended service.
  • Hazardous-Area Motor Options
  • Controlled Impeller Tip Clearance
  • Bonded and Grounded Metalwork
  • Protected Cable Entries
견적 요청 제품 찾아보기

상품 소개

This explosion-proof axial exhaust fan is configured as a complete hazardous-area ventilation assembly rather than relying on one blade material alone. The long-cased steel housing, impeller and casing material pairing, running clearance, compatible hazardous-area motor, external terminal enclosure, bonding provisions and cable glands are selected together for the intended gas group, temperature class and Zone or Class. External electrical access and bolted duct flanges allow the rotating and wiring components to be inspected without removing the complete duct run.

주요 기능

The impeller alloy, casing contact material and running clearance are selected together as one spark-resistant construction instead of treating aluminum blades alone as protection.

External Ex d flameproof or Ex e increased-safety motor arrangements can be matched to the electrical classification and conveyed atmosphere.

A metal terminal enclosure, hazardous-area cable glands and identified bonding points provide a controlled electrical connection at the fan body.

Heavy-gauge welded casing, spun flanges and external stiffeners help preserve the specified tip clearance during horizontal or vertical installation.

고객 제품 관심사

Ventilation in flammable-vapor areas must move the required air while the complete mechanical and electrical construction addresses foreseeable ignition sources.

An unsuitable impeller and casing material combination can produce friction or impact sparks even when one component is aluminum.The material pairing, tip clearance, casing rigidity and inspection access are selected and maintained as one spark-resistant fan construction.
A motor, terminal box or cable gland that does not match the hazardous-area classification can remain an electrical ignition source.A compatible Ex motor arrangement, protected terminal enclosure and hazardous-area cable glands are selected for the intended Zone or Class, gas group and temperature class.
Static charge can accumulate across isolated metal duct and fan sections.Dedicated bonding lugs and grounded conductive connections maintain electrical continuity across the casing, flanges and adjacent ductwork.
Corrosion or casing distortion can reduce blade clearance after prolonged chemical-service operation.A reinforced corrosion-protected shell and accessible inspection points support routine checks of coating condition, fasteners and running clearance.

일반적인 응용 프로그램

Solvent storage and dispensing-room exhaustBattery electrolyte mixing and filling ventilationPharmaceutical alcohol-process extractionPaint and coating preparation areasChemical cleanroom support-space exhaust

기술 매개변수

Typical structural ranges for a configurable external-motor axial fan intended for hazardous-area exhaust service are listed below.

핵심 재료Hot-dip galvanized or epoxy-coated steel long casing with a manufacturer-selected impeller/casing material pairing, compatible hazardous-area motor and external terminal enclosure
패널 두께3.0-6.0 mm heavy-gauge welded casing thickness
유효 폭450-1600 mm nominal clear fan diameter
최대 길이Up to 3000 mm overall length including external motor supports and terminal enclosure
강철 면면 두께3.0-6.0 mm carbon-steel casing, flange and reinforcement plate
코어 밀도Approximately 7800-7900 kg/m³ for the reinforced carbon-steel casing
열전도도 (Thermal Conductivity)Approximately 45-55 W/(m·K) for the carbon-steel shell and support structure
표면 마무리Hot-dip galvanizing or chemical-resistant coating with corrosion-resistant impeller finish and designated bonding points
접합 유형Welded long casing with bolted circular flanges, maintained impeller clearance, bonding lugs and hazardous-area cable glands
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Ex d flameproof or Ex e increased-safety motor and terminal arrangement selected for the intended atmosphereZone 1 or Zone 2, or Class I Division 1 or 2 electrical configuration where required by the site classificationImpeller and casing material pairing selected for the applicable spark-resistant construction levelFlexible connectors, safety guard, drain, inspection cover and vertical mounting supports

Planning a Explosion-Proof Axial Exhaust Fan specification?