A compact rotary drive that clamps directly to a damper shaft and converts an electrical control signal into repeatable blade position or safety closure.
  • Universal Direct Shaft Clamp
  • Adjustable Mechanical End Stops
  • Manual Gear Release
  • On-Off Floating or Proportional Control
見積もりリクエスト 製品案内

商品紹介

The HVAC damper actuator combines a reversible electric motor, reduction gear train, position electronics and universal shaft clamp in one sealed housing. It mounts directly on a round or square damper shaft, with an anti-rotation bracket preventing the body from turning. Adjustable stops limit the travel angle, while a manual release allows the blade position to be set during installation. Non-spring and spring-return versions support ordinary modulation, shut-off and selected safety-position duties.

主要な特徴

A universal clamp accepts common round and square shafts without a separate crank linkage.

Mechanical end stops define the usable rotation range and protect the damper linkage from overtravel.

Manual override disengages the gear train for blade positioning during installation or service.

Control variants cover two-position, three-point floating and proportional analog operation with optional feedback.

お客様の製品に関する懸念事項

Actuator reliability depends on correct torque, shaft geometry, travel direction, supply voltage and a fail-position strategy matched to the controlled damper.

The actuator reaches full torque but the damper still leaks because the blade bank needs more closing force.Required torque is calculated from blade area, differential pressure, seal drag and linkage efficiency before selecting the drive.
A loose shaft clamp slips after repeated reversals.A correctly sized self-centering clamp and anti-rotation bracket secure both the shaft and actuator housing.
The control signal opens the damper when the sequence expects closure.Selectable rotation direction and clearly set end stops align actuator travel with the blade position indication.
Loss of power leaves an isolation damper in an uncontrolled intermediate position.A spring-return model drives the shaft to the specified safety endpoint without relying on the controller.

典型的な用途

Volume control dampersOutside and return-air dampersVAV terminal bladesShut-off and isolation dampersFire and smoke damper drive systems

技術的なパラメータ

Typical physical construction ranges for a direct-coupled rotary HVAC damper actuator are listed below.

コア材料Glass-fiber-reinforced engineering polymer housing with steel gear train and universal steel shaft clamp
パネルの厚さ2.5–4.0 mm molded actuator housing wall
有効幅100–180 mm typical actuator body width
最大長さUp to 250 mm overall actuator body length including shaft clamp
鋼鉄の厚さを直面する1.5–3.0 mm zinc-plated shaft clamp and anti-rotation bracket
コア密度Approximately 1200–1400 kg/m³ for reinforced polymer housing material
熱伝導率Approximately 0.20–0.35 W/(m·K) for the reinforced polymer enclosure
表面仕上げOrange or black impact-resistant molded housing with zinc-plated clamp hardware
ジョイントタイプDirect universal shaft clamp with anti-rotation bracket, adjustable stops and protected cable entry
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

24 V or mains-voltage supplyNon-spring or spring-return mechanismOn-off, floating, 0–10 V or network controlAuxiliary switches and position feedback