Tank de stockage WFI par

An insulated, drainable 316L stainless steel vessel for buffering Water for Injection in hot or periodically heat-sanitized recirculating systems.
  • Hot-WFI-ready insulated construction
  • Drainable 316L contact surfaces
  • Heated venting and sanitary instrumentation
Demander un devis. Browse les produits

Introduction de produit

The WFI storage tank maintains useful system volume between generation and a continuously circulating distribution loop. Its drainable vessel geometry, hygienic internal finish and spray-cleaning arrangement reduce retained water, while insulation and a stainless outer jacket support hot storage or thermal sanitization strategies. Level and temperature instruments coordinate generation, recirculation and utility control without introducing unnecessary wetted branches.

Key Features

316L stainless steel product-contact vessel

Insulated shell with cleanable stainless outer jacket

Drainable dished bottom and low-point outlet

Heated hygienic vent-filter housing option

Internal spray device for defined wetting coverage

Sanitary level and temperature instrumentation

Side manway for controlled inspection access

Support legs arranged for outlet and piping clearance

Préoccupations du client produit

WFI storage must preserve hygienic conditions while managing temperature, air exchange, changing demand and full-system sanitization.

Stored WFI loses temperature during low demandSpecify continuous loop circulation with correctly sized insulation and a jacket or external heat exchanger matched to the thermal strategy.
Condensation compromises the vent-filter assemblyUse a drainable heated vent housing and controlled steam or electric tracing to keep the filter within its intended operating envelope.
Residual water remains in the tank after drainingCombine a dished bottom, central low-point outlet and drainable instrument branches with the installed vessel orientation.
Generation cycles do not follow plant demandUse continuous level measurement and independent alarm switches to coordinate still output, loop pump protection and operating reserve.

Les applications typiques

Aseptic pharmaceutical manufacturingParenteral drug productionBiopharmaceutical processingVaccine and biologics facilitiesSterile formulation and equipment-rinse utilities

Paramètres techniques

The vessel volume, thermal design and connection schedule are selected for loop return temperature, peak demand, sanitization method and installation constraints.

Matériaux de base316L stainless steel product-contact shell, heads, nozzles and internal fittings with hygienic insulation system
Panneau épaisseurInner vessel shell typically 2.0–8.0 mm according to diameter and design condition
Largeur effectiveJacketed vessel diameter typically 700–2600 mm
Longueur maximaleOverall insulated vessel height typically up to 5500 mm
Acier face épaisseurStainless outer insulation jacket typically 0.8–1.5 mm
Densité Core316L stainless steel density approximately 8000 kg/m³
Conductivité thermique316L stainless steel approximately 15 W/(m·K) at ambient temperature
surface finieHygienic mechanically polished or electropolished internal surface with satin stainless outer jacket
Type jointOrbital-weld-ready sanitary tube stubs with drainable clamp or welded instrument connections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Hot-storage or ambient-storage configurationMineral wool or closed-cell insulationSteam, electric or hot-water vent heatingRotary spray head or fixed spray deviceLoad-cell, radar or pressure level measurementTemperature and conductivity transmittersPressure-vacuum protectionHeating jacket or external loop heat exchanger interface