Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Systèmes de distribution d'air Cleanroom

Amortisseur de fermeture motorisé

A compact circular isolation damper whose electric or pneumatic actuator rotates one sealed blade between defined open and closed positions.
  • Positive Open-Close Operation
  • Sealed Single Butterfly Blade
  • Selectable Spring-Return Position
  • External End-Position Indication
Demander un devis. Browse les produits

Introduction de produit

The motorized shut-off damper inserts a single circular blade into a short galvanized duct body. A direct-mounted actuator rotates the shaft through approximately ninety degrees to isolate or restore airflow. A perimeter blade seal reduces closed leakage, and the shaft mark provides a mechanical position reference visible outside the duct. Spring-return actuator versions move to the specified open or closed position when power or control pressure is lost, while auxiliary switches can confirm the endpoints.

Key Features

A short round casing fits isolation points where a multiblade rectangular frame would require excessive space.

The single blade and direct shaft connection provide a simple open-close movement with few linkage components.

A compressible perimeter seal restricts leakage around the circular blade in the commanded closed position.

Spring-return and end-switch options support fail-position sequences and remote proof of isolation.

Préoccupations du client produit

Reliable shut-off requires the correct fail position, enough actuator torque for seal compression and access to the drive after insulation and ceiling closure.

A modulating damper is used for isolation but never reaches a repeatable sealed endpoint.Defined open-close end stops and a matched actuator focus the mechanism on dependable shut-off travel.
Loss of control power leaves the process branch open.A spring-return actuator moves the blade to the selected normally closed safety position.
Duct insulation hides the shaft mark and actuator release.An extended mounting bracket keeps position indication, wiring and manual override outside the insulation layer.
Excessive differential pressure twists the shaft before the seal seats.Blade diameter, shaft size and actuator torque are selected together for the maximum closed pressure.

Les applications typiques

Cleanroom branch shutdownLaboratory exhaust isolationEquipment purge and standby ductsAirlock supply and return isolationSmall process ventilation connections

Paramètres techniques

Representative construction ranges for a circular motorized shut-off damper are shown below.

Matériaux de baseGalvanized or stainless-steel circular butterfly blade with elastomer perimeter seal and steel shaft
Panneau épaisseur1.0–1.5 mm single shut-off blade
Largeur effective80–630 mm nominal circular duct diameter
Longueur maximale200–500 mm overall casing length in the airflow direction
Acier face épaisseur0.8–1.2 mm galvanized or stainless circular casing
Densité CoreApproximately 7850 kg/m³ for the steel blade and shaft assembly
Conductivité thermiqueApproximately 45–55 W/(m·K) for galvanized carbon-steel construction
surface finieMill-galvanized, powder-coated or passivated stainless-steel air path
Type jointRound slip-fit or flanged casing with sealed butterfly blade and direct external actuator
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Electric or pneumatic actuatorNormally open or normally closed spring returnAuxiliary open-close switchesGalvanized, powder-coated or stainless-steel construction