Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
FFU et équipement de purification de l'air terminal

EC

A local low-voltage controller that adjusts one EC fan filter unit through an isolated 0–10 V or PWM command and displays its operating setpoint.
  • Local Airflow Setpoint
  • Isolated 0-10 V Output
  • Remote Enable Input
  • Compact Wall Mount
Demander un devis. Browse les produits

Introduction de produit

The EC FFU speed controller provides a simple room-side interface for one fan filter unit or a small matched pair. A sealed rotary knob sets the airflow command, and an optional digital display shows percentage, voltage or fan feedback. Galvanic isolation protects the low-voltage signal from field wiring noise, while a remote enable input allows a door interlock, occupancy relay or supervisory panel to place the FFU into standby. The controller regulates the EC motor command only; mains isolation and motor protection remain within the FFU electrical assembly.

Key Features

A positive-action rotary setpoint enables quick local adjustment without opening an electrical cabinet.

The isolated analogue output reduces ground-loop errors on long control cables.

Remote enable contacts permit standby operation from an external cleanroom sequence.

A removable terminal plug speeds replacement without disturbing fixed field conductors.

Préoccupations du client produit

A standalone EC FFU needs stable speed adjustment without exposing mains wiring or forcing operators to reach above the cleanroom ceiling.

The factory trim potentiometer is inaccessible after the FFU is installed above the ceiling.A room-side rotary control places the setpoint at a convenient operating location.
Voltage drop and electrical noise make the fan speed drift on a long signal cable.An isolated 0-10 V output and referenced common improve command stability.
The fan must enter standby when a process tool stops, but its speed setting should be retained.A separate enable input disables the output without moving the setpoint knob.
Replacing a failed controller requires every conductor to be removed individually.A keyed pluggable terminal block disconnects the complete low-voltage harness as one assembly.

Les applications typiques

Single EC fan filter unitsClean benches and mini-environmentsIndependent ceiling FFU zonesEquipment fan filter modulesLaboratory clean-air stations

Paramètres techniques

Representative physical ranges for a local EC FFU speed controller are listed below.

Matériaux de baseMicrocontroller board with isolated 0-10 V or PWM output, sealed potentiometer and optional digital display
Panneau épaisseur45-90 mm installed controller depth
Largeur effective86-150 mm faceplate width
Longueur maximaleUp to 200 mm enclosure height
Acier face épaisseur0.8-1.0 mm stainless or powder-coated steel mounting plate when specified
Densité CoreApproximately 1800-1900 kg/m³ nominal density of the FR-4 substrate used in the EC speed controller
Conductivité thermiqueApproximately 0.25-0.40 W/(m·K) through the compact FR-4 board in the EC speed controller
surface finieWhite flame-retardant polymer or cleanroom-white powder-coated metal faceplate with blue control knob
Type jointFlush or surface wall mount with keyed pluggable low-voltage terminals or RJ-style control connector
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Rotary-only or digital display version0-10 V, PWM or EC motor-specific outputRemote enable and fault inputFlush wall plate or surface enclosure