Hochtemperatur-Doppelwand - Auspuffkanal
- 316L Stainless Inner Liner
- Integrated Mineral-Fiber Insulation
- Double-Wall Modular Body
- Up to 600°C Dry Service
Produkteinführung
High-temperature double-wall exhaust duct contains hot dry process gases within a welded stainless inner liner while mineral-fiber insulation reduces heat transfer to the external casing. Straight cylindrical modules connect with precision male-female ends, high-temperature seals where appropriate and external locking bands. The inner column can expand relative to the outer shell, limiting thermal stress through long routes. The system is suited to ovens, sterilizers, generators and selected industrial exhaust sources where conventional HVAC sheet duct and insulation are inadequate.
Key Features
Mineral-fiber insulation lowers outer-wall temperature and limits heat loss from the conveyed exhaust.
Modular locking-band joints allow sections, bends and access components to be assembled without broad field welds.
Independent inner-wall movement accommodates thermal expansion along extended exhaust routes.
Kunden Produktbedenken
A hot exhaust route must contain temperature and pressure while allowing thermal growth and keeping adjacent surfaces within a manageable heat exposure.
Typische Anwendungen
Technische Parameter
Representative construction ranges for modular high-temperature double-wall exhaust duct are shown below.
| Core Material | High-temperature mineral-fiber insulation between stainless steel walls |
|---|---|
| Panel Dicke | 25–50 mm insulation thickness |
| Effektive Breite | 100–1200 mm nominal internal diameter |
| Maximale Länge | 1000 mm per standard modular straight section |
| Stahl facing Dicke | 0.6–1.0 mm 316L inner liner and 0.5–0.7 mm 304 outer casing |
| Kerndichte | 100–180 kg/m³ high-temperature mineral fiber |
| Thermische Leitfähigkeit | 0.040–0.060 W/(m·K), depending on insulation and mean temperature |
| Oberfläche Finish | Bright or brushed stainless inner liner with stainless outer casing |
| Gemeinsamer Typ | Male-female modular socket with temperature-rated seal and external locking band |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a High-Temperature Double-Wall Exhaust Duct specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch