AC Fan Filter Einheit
- PSC AC Induction Motor
- Local Rotary Speed Control
- Forward-Curved Blower Wheel
- Wide Voltage Configuration Range
Produkteinführung
The AC fan filter unit uses a permanent-split-capacitor induction motor and forward-curved blower wheel to produce filtered supply air from a conventional single-phase circuit. A local rotary controller adjusts motor voltage for commissioning and periodic rebalance, while the accessible junction box keeps mains connections separate from the filter chamber. The mechanically simple drive is suitable where individual unit control and economical replacement are preferred over digital networking.
Key Features
A guarded rotary potentiometer permits local airflow trimming without software or a communication network.
The forward-curved wheel develops useful pressure at moderate rotational speed in a compact top-mounted scroll.
A separate terminal enclosure keeps line-voltage connections away from the clean-air path.
Kunden Produktbedenken
An AC FFU is often selected for straightforward local operation, so the design must balance first cost, controllability and service access.
Typische Anwendungen
Technische Parameter
Representative dimensions and materials for a locally controlled PSC-motor AC fan filter unit are shown below.
| Core Material | Galvanized-steel plenum, PSC AC motor, forward-curved centrifugal wheel and micro-glass HEPA or ULPA filter |
|---|---|
| Panel Dicke | 320-420 mm overall module depth |
| Effektive Breite | 575 - 1170 mm Nenndecken-Gitterbreite |
| Maximale Länge | Bis zu 1170 mm Standardmodullänge |
| Stahl facing Dicke | 0.8-1.2 mm galvanized-steel plenum and service panels |
| Kerndichte | Approximately 85-115 kg/m³ nominal compacted density of the micro-glass final-filter pack |
| Thermische Leitfähigkeit | Approximately 0.035-0.045 W/(m·K) for the dry final-filter pack installed in the AC-driven FFU |
| Oberfläche Finish | Natural passivated zinc interior with optional white powder-coated exterior and diffuser |
| Gemeinsamer Typ | Ceiling-grid flange with neoprene perimeter gasket and a compression-sealed removable filter frame |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a AC Fan Filter Unit specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch