A corrosion-resistant 40 mm modular aluminum header with a crown-fed 25 mm gooseneck drop, full-bore push-fit joints, supported outlet valve and dedicated low-point condensate drain.
  • 40 mm header with 25 mm service drop
  • Full-bore push-to-connect joints
  • Crown take-off and low-point drainage
견적 요청 제품 찾아보기

상품 소개

Clean Compressed Air Piping distributes already-treated air between the compressor-room treatment train and cleanroom equipment without the rust scale and rough internal surfaces associated with conventional ferrous pipe. The selected catalogue-scale assembly uses two smooth 40 mm blue aluminum header sections and one 25 mm gooseneck branch assembled with reusable push-to-connect fittings. Its reducing tee faces upward from the header crown, then two elbows carry the branch over and down to a single red-handled point-of-use valve. The header is supported on snap-shut clips and pitched slightly toward one dedicated low-point drain, limiting bottom-fed dead legs and making moisture removal accessible. The piping does not filter, dry, sterilize or regulate air on its own; delivered air quality remains a property of the complete treatment, installation and maintenance system.

주요 기능

Smooth extruded aluminum tube resists internal corrosion and limits scale that can contaminate downstream clean-air branches

A 40 mm main header supplies a 25 mm service drop while preserving a visibly clear distinction between distribution and point-of-use pipe sizes

Full-bore push-to-connect fittings avoid threaded or welded joints along the modular aluminum run and support later reconfiguration

The crown-facing reducing tee and raised gooseneck branch discourage settled condensate from flowing directly into the service drop

A dedicated drain valve at the pitched header's low end provides one accessible condensate-removal location without creating multiple hidden pockets

The red-handled ball valve isolates the single equipment outlet without turning the piping kit into a regulator or filter assembly

Six snap-shut clips on three metal support rails restrain the header and drop while leaving joints visible for inspection

Distinct blue tube, black fittings, red isolation handle and natural-metal supports provide conventional compressed-air identification and clear maintenance recognition

고객 제품 관심사

Reliable clean-air delivery depends on network sizing, drainage geometry, support spacing, joint preparation and the upstream treatment train rather than pipe diameter or color alone.

An undersized header or excessive number of fittings can leave equipment below its required inlet pressure during simultaneous demandSize the header from peak coincident flow, total equivalent length and minimum supply pressure, then check the complete route against a loaded-system pressure-drop objective of approximately 0.07-0.14 bar (1-2 psi) or less.
A branch taken from the bottom of the main can carry condensate directly to valves, instruments or production equipmentUse the upward crown-facing tee and raised gooseneck before the vertical drop, pitch the header toward the separate low-point drain and keep that drain accessible.
Poorly prepared tube ends or damaged seals can create small leaks that waste energy and destabilize branch pressureCut square, deburr and clean each tube, mark the insertion depth, inspect the gripping and NBR sealing rings, and complete leak testing before service.
Unsupported pipe movement can load fittings and cause alignment or sealing problems during pressure and temperature cyclesUse the specified snap-shut clips on independent support rails, maintain manufacturer spacing and allow controlled expansion without hanging unrelated equipment from the pipe.
A clean distribution pipe may be mistaken for a device that creates sterile, oil-free or ultra-dry airDefine the required purity at each outlet and provide the appropriate upstream compressor, dryer, coalescing, adsorption and final filtration stages separately from this distribution kit.

일반적인 응용 프로그램

Pharmaceutical cleanroom pneumatic tools and machine branches after central air treatmentElectronics and semiconductor assembly equipment supplied by dry filtered compressed airFood and beverage packaging lines where corrosion-resistant distribution helps protect air qualityMedical-device production cells using centrally conditioned utility airLaboratory instrument branches and controlled blow-off stationsModular clean manufacturing lines that require accessible extensions or point-of-use changes

기술 매개변수

The selected purchasable display identity is a 40 mm OD modular aluminum main with a 25 mm crown-fed service drop. It fixes two 40 mm header tubes, three 25 mm branch tubes, one 40 x 25 mm reducing tee, two 25 mm elbows, one 25 mm straight union, one threaded outlet block, one red-lever service valve, two different header end caps, one compact low-point drain valve, six snap-shut clips and three galvanized support rails. Comparable manufacturer systems use smooth extruded aluminum tube, full-bore push-fit joints, engineered-polymer fittings and NBR seals, with temperature-dependent maximum system ratings commonly reaching about 13-16 bar. This page limits the selected normal operating envelope to 10 bar; actual allowable pressure, flow and support spacing follow the final component family, temperature, route and local design requirements.

핵심 재료6063-T5-class extruded aluminum tube, glass-reinforced polyamide fitting and clip bodies, NBR joint seals, nickel-plated brass valves and galvanized steel support rails
패널 두께Representative 1.5-2.0 mm aluminum tube-wall range for the selected 40 mm modular main
유효 폭40 mm main-header outside diameter with a 25 mm point-of-use drop
최대 길이Up to 6000 mm standard straight-tube length before field cutting and modular assembly
강철 면면 두께0 mm steel facing on the aluminum pipe; representative galvanized support-rail sections are 2.0-3.0 mm
코어 밀도Approximately 2700 kg/m³ representative density for the 6063-T5-class aluminum tube
열전도도 (Thermal Conductivity)Approximately 200-210 W/(m·K) at 20-25°C for representative 6063-T5-class aluminum tube
표면 마무리RAL 5012 blue exterior polyester powder coat, smooth pale-silver conversion-treated bore, matte-black fittings and clips, red service-valve lever and galvanized-silver supports
접합 유형40 mm and 25 mm full-bore push-to-connect joints with internal gripping rings and NBR seals, including one crown-facing 40 x 25 mm reducing tee and a two-elbow gooseneck drop
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

20, 25, 40, 50 and 63 mm modular pipe families selected from flow, route length and allowable pressure dropBlue compressed-air, gray vacuum or green inert-gas identification finishes where supported by the selected manufacturer familyStraight unions, reducing couplings, equal or reducing tees, 45-degree bends and 90-degree elbows for the required route geometryCrown-fed gooseneck drops, quick-assembly branch saddles and threaded outlet blocks for equipment connectionsNickel-plated brass, polymer or stainless-steel isolation valves selected for the service environmentManual, timed or automatic low-point drains supplied as separate compatible accessoriesWall, ceiling or rack support layouts with clip spacing and expansion allowance matched to pipe size and temperature rangeRing-main or branched distribution layouts sized to the real coincident demand and point-of-use pressure requirement