Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

Scroll Compresseur de refroidissement

A compact liquid chiller using multiple hermetic scroll compressors for quiet staged cooling and straightforward circuit redundancy.
  • Multiple Hermetic Scrolls
  • Fine Capacity Staging
  • Low-Vibration Operation
  • Compact Service Layout
Demander un devis. Browse les produits

Introduction de produit

The scroll compressor chiller combines several hermetic scroll compressors in independent or paired refrigerant circuits. Each orbiting scroll compresses gas continuously with few moving parts, producing low vibration and a compact enclosure. Compressor staging matches part-load demand in small increments, and a circuit can remain off or be serviced while other circuits operate. Air-cooled versions use condenser fans and finned coils; water-cooled versions use a compact condenser connected to a water loop.

Key Features

Multiple scroll compressors create smaller operating steps than one large fixed-capacity compressor.

Hermetic construction and continuous compression reduce external shaft seals and vibration.

Independent circuits maintain partial cooling when one circuit is unavailable.

Compact compressor dimensions support packaged chillers and modular plant layouts.

Préoccupations du client produit

Scroll chillers rely on coordinated staging and adequate water volume to prevent excessive starts under light or rapidly changing load.

The chiller cycles when the active process load is smaller than its first capacity step.Multiple smaller compressors and appropriate buffer volume lengthen operating cycles.
Simultaneous compressor starts create a large electrical demand peak.Timed staging starts compressors sequentially as leaving-water demand increases.
One refrigerant leak removes the entire cooling plant.Independent circuits isolate the affected section while remaining circuits continue.
Condenser fouling raises pressure and trips compressors during hot weather.Accessible coil faces and staged fan control maintain design condenser airflow.

Les applications typiques

Small and medium cleanroom systemsLaboratory chilled-water loopsMedical-device facilitiesProcess equipment coolingPhased pharmaceutical projects

Paramètres techniques

Representative enclosure and evaporator insulation data for a packaged scroll chiller are listed below.

Matériaux de baseClosed-cell synthetic NBR foam on the brazed-plate evaporator and suction lines
Panneau épaisseur1.0–1.5 mm removable equipment panels
Largeur effective800–2200 mm nominal equipment width
Longueur maximaleUp to 7000 mm for multi-circuit air-cooled configuration
Acier face épaisseur1.0–2.0 mm galvanized frame and enclosure panels
Densité Core40–60 kg/m³ closed-cell synthetic NBR insulation
Conductivité thermique≤0.036 W/(m·K) at 20°C for the NBR insulation
surface finiePolyester powder-coated galvanized steel with corrosion-resistant heat-exchanger option
Type jointWelded base with bolted service panels and grooved or threaded hydronic connections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Air-cooled or water-cooled condenserFixed-stage or variable-speed lead scrollIntegrated pump and buffer vesselLow-ambient, low-noise and partial heat-recovery packages

Planning a Scroll Compressor Chiller specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact