Gas Leak Detection System
- Continuous fixed-point or remote sample monitoring
- Modular sensor and pump access from the instrument front
- Local alarm indication with relay and network integration
Produkteinführung
The Gas Leak Detection System is a compact fixed extractive monitor for identifying selected toxic, flammable or oxygen hazards around gas cabinets, process tools and utility service areas. A controlled internal pump draws a sample from a local inlet or remote tube to a replaceable sensor cartridge. The instrument combines a color status display, keypad, event memory, alarm and fault relays, analogue signalling and digital communications in one wall- or rail-mounted enclosure. Gas type, range, sample material, alarm logic and automatic response are selected for the actual hazard; the monitor does not replace ventilation, source isolation or a documented emergency-response design.
Key Features
A modular sensor cartridge lets the configured gas chemistry be serviced without replacing the complete instrument
Controlled sample flow and flow diagnostics help identify blocked, disconnected or leaking sample paths
A multicolor display separates normal, warning, alarm and fault conditions at the point of use
Independent alarm and fault relay contacts support annunciation, ventilation commands or a separately engineered shut-off circuit
Analogue and digital outputs provide a practical link to building, process and safety monitoring platforms
Password-controlled setup reduces unintended changes to gas identity, range and alarm thresholds
Event logging supports investigation of alarms, faults, maintenance and configuration changes
Wall and DIN-rail mounting options suit gas rooms, service chases, tool subfabs and equipment skids
Front-access pump and sensor modules reduce the clearance needed for routine service
Kunden Produktbedenken
Reliable leak warning depends on the selected sensing chemistry and the complete sample path, not on the display alone. Detector location, tubing, alarm actions, proof testing and maintenance must be matched to the real release scenario.
Typische Anwendungen
Technische Parameter
The selected display basis is a compact four-sensor-capable fixed extractive monitor in a polycarbonate enclosure, approximately 136 mm high, 83 mm wide and 152 mm deep, operating from nominal 24 VDC with wall or DIN-rail mounting. The site's fixed ten-row schema uses panel-oriented labels; here Panel Thickness means instrument depth and Steel Facing Thickness records that the molded cover has no separate steel facing. Gas cartridge, sample tube, filter, range, relay logic, communications and power arrangement remain application-selected.
| Core Material | Molded polycarbonate instrument cover on a zinc-plated steel mounting bracket, with internal pump, electronics and replaceable smart sensor cartridge |
|---|---|
| Panel Dicke | 152 mm nominal overall enclosure depth for the selected compact extractive-monitor basis |
| Effektive Breite | 83 mm nominal enclosure width for the selected catalogue display basis |
| Maximale Länge | 136 mm nominal enclosure height, excluding external sample tubing and service clearance |
| Stahl facing Dicke | 0 mm separate facing; the outer cover is molded polycarbonate and the zinc-plated steel bracket is a distinct mounting component |
| Kerndichte | Approximately 1200 kg/m³ representative density for an unfilled polycarbonate enclosure material |
| Thermische Leitfähigkeit | Approximately 0.20 W/(m·K) near 23°C for representative unfilled polycarbonate |
| Oberfläche Finish | Light-gray molded polymer cover, dark display lens, distinct green/yellow/red status indicators and corrosion-protected metal bracket |
| Gemeinsamer Typ | Removable front, pump and sensor modules on a wall or DIN bracket, with compression sample/exhaust tube ports and terminal or Ethernet connections |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Gas Leak Detection System specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch