실험실 음압 제어 시스템
- Closed-Loop Room Pressure Control
- Supply and Exhaust Flow Tracking
- Dual VAV Valve Actuation
- Local HMI, Alarms and BAS Connectivity
상품 소개
The Laboratory Negative Pressure Control System is a fixed room-HVAC control package for laboratories that must maintain inward directional airflow relative to an adjacent space. A low-pressure transmitter measures the room-to-reference differential through two dedicated pressure tubes, while separate airflow pickups report the condition of the supply and exhaust terminals. The programmable controller compares the measured differential and airflow balance with the configured operating state, then commands the two VAV actuators to maintain the intended exhaust-over-supply offset without treating a fixed damper position as proof of room pressure. The illustrated purchasable assembly includes one powder-coated control cabinet, a local HMI, three status indicators, an alarm acknowledge control, a 24 V power supply, programmable controller and I/O, a network gateway, one room-pressure transmitter, one supply VAV valve and one exhaust VAV valve on an aluminum service frame. It is a control and demonstration package rather than a portable fan or filtration unit; room leakage, terminal airflow range, fan capacity, door behavior and the project risk assessment determine the final pressure setpoint and sequence.
주요 기능
Independent supply and exhaust VAV channels support airflow-offset control, minimum ventilation limits and coordinated recovery when a hood, door or room operating mode changes the air balance.
The door-mounted HMI, green-amber-red status indication and acknowledge control give operators a local view of normal, warning and alarm states before the signals are forwarded to the building system.
A segregated 24 V supply, programmable controller, I/O terminals and selectable network gateway keep sensor, actuator, alarm-relay and BAS connections organized for commissioning and service.
고객 제품 관심사
Stable laboratory containment depends on the measured relationship between room pressure, supply flow, exhaust flow and changing operating conditions rather than on a single fixed damper command.
일반적인 응용 프로그램
기술 매개변수
Representative construction values for the illustrated freestanding twin-valve control assembly are listed below; pressure range, valve diameter and airflow capacity are selected for the actual room and duct design.
| 핵심 재료 | EN AW-6063-T6 aluminum extrusion frame and mounting plate, galvanized-steel VAV bodies, a RAL 7035 powder-coated steel controller enclosure, engineering-plastic HMI, sensor and actuator housings, copper conductors and flexible pressure tubing |
|---|---|
| 패널 두께 | 3.0 mm nominal aluminum equipment mounting plate |
| 유효 폭 | 900 mm assembled service-frame width for the selected twin-valve configuration |
| 최대 길이 | Up to 1200 mm overall assembled frame height including the support feet |
| 강철 면면 두께 | 1.5 mm nominal powder-coated controller-enclosure sheet |
| 코어 밀도 | 2700 kg/m³ for representative EN AW-6063-T6 aluminum frame material |
| 열전도도 (Thermal Conductivity) | 201 W/(m·K) for representative EN AW-6063-T6 aluminum at 20 °C |
| 표면 마무리 | Natural anodized aluminum frame, RAL 7035 light-gray powder-coated cabinet, neutral galvanized-silver valve bodies, blue actuator housings, a white sensor module, black tubing, a dark-navy HMI and green-amber-red indicators |
| 접합 유형 | Bolted T-slot frame joints, bolted cabinet and VAV brackets, gasketed cable entries, barbed differential-pressure tube connections, sleeve or flanged duct interfaces and removable terminal-block wiring |
| 사용자 정의 | 의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다. |
사용 가능한 옵션
Planning a Laboratory Negative Pressure Control System specification?
치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.