상품 소개
The air shower blower draws return air through the unit filters and discharges it back toward the nozzle plenum. A forward-curved centrifugal wheel operates inside a galvanized scroll housing to develop the airflow and pressure needed by multiple high-velocity nozzles within a compact cabinet. The motor mounts directly to the housing and the rectangular discharge connects to the internal plenum. Replacement selection must match wheel rotation, inlet and outlet geometry, electrical supply, motor power and mounting-foot pattern.
주요 기능
A formed scroll housing directs wheel discharge into the air-shower nozzle plenum.
Direct motor mounting eliminates external belts and simplifies service replacement.
Flanged inlet, outlet and mounting points support secure installation inside the equipment cabinet.
고객 제품 관심사
A replacement blower must reproduce the original airflow direction and fit the air-shower recirculation path without cabinet modification.
일반적인 응용 프로그램
기술 매개변수
Typical construction ranges for compact air-shower centrifugal blowers are shown below.
| 핵심 재료 | Forward-curved galvanized-steel centrifugal wheel with copper-wound electric motor |
|---|---|
| 패널 두께 | 180-400 mm nominal blower housing depth |
| 유효 폭 | 250-550 mm nominal scroll-housing width |
| 최대 길이 | Up to 700 mm overall blower and motor length |
| 강철 면면 두께 | 0.8-1.5 mm galvanized-steel scroll housing |
| 코어 밀도 | 7800-7850 kg/m³ for steel wheel and housing components |
| 열전도도 (Thermal Conductivity) | 45-60 W/(m·K) for steel housing components |
| 표면 마무리 | Natural zinc-coated silver housing with black motor and insulated cable |
| 접합 유형 | Bolted scroll casing with direct motor flange, rectangular outlet and foot mounting |