ผู้จัดจําหน่ายแบบครบวงจรสําหรับอุปกรณ์ห้องคลีนรูมและสิ่งจําเป็นสําหรับสิ่งอํานวยความสะดวกปลอดเชื้อการสนับสนุนโครงการระหว่างประเทศ
Open mobile navigationClose mobile navigation
อุปกรณ์ห้องคลีนรูมเฉพาะอุตสาหกรรม

ห้องปฏิบัติการถ่ายโอนสัตว์

A wall-mounted vivarium pass-through that combines opposing interlocked observation doors with one recirculating HEPA airflow module for transferring closed animal transport boxes across a room barrier.
  • ฝ่ายตรงข้ามประตูที่เชื่อมต่อกัน
  • Single Recirculating HEPA Module
  • 485 mm Clear Chamber Width
  • Wall-Mounted Barrier Transfer
ขอใบเสนอราคา เรียกดูสินค้า

การแนะนําสินค้า

The Animal Laboratory Transfer Chamber is a through-wall enclosure for moving closed mouse or rat transport boxes between a receiving side and a controlled vivarium side without opening a personnel doorway. The selected double-door configuration has two opposing gasket-compression observation doors governed by a one-door-at-a-time interlock. A single top-mounted blower returns chamber air through one HEPA cartridge, directs it downward through the ceiling diffuser and collects it at two low-level return slots. The satin-brushed AISI 304 chamber has a coved empty interior, a rear mounting flange and clear glazing for load checks from either room. One differential-pressure gauge, green operating lamp, amber lock lamp and speed-control knob provide local status without converting the chamber into a mobile animal cart, open cage-changing station, medical supply pass box or waste hatch. The illustrated chamber contains no shelf, removable tray, UV lamp or sterilization system.

คุณสมบัติที่สําคัญ

The opposing door interlock permits only one transfer side to be opened at a time, limiting a direct air path through the vivarium barrier while the other gasketed door remains secured.

One compact recirculating HEPA-and-blower module supplies the ceiling diffuser and receives air from the two lower return slots, providing an active transfer space without a second fan or exhaust duct.

Large colorless observation windows allow staff on both sides to verify chamber occupancy and door condition before operating the next interlocked door.

The coved stainless interior, low-profile return slots and front-access filter compartment keep the transfer zone free of loose shelves and simplify routine wipe-down and service access.

ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์

Animal-facility receiving points must move bulky closed transport containers across a room barrier while controlling door sequence, chamber cleanliness and load visibility.

Opposing transfer doors can create a direct path between rooms if both are opened together.The one-door-at-a-time interlock keeps the opposite gasket-compression door secured throughout loading and unloading.
A static chamber can retain airborne particles introduced during repeated door openings.The single recirculating blower moves chamber air through one HEPA cartridge, then down from the ceiling diffuser to the low-level return slots.
Animal transport boxes require more clear depth and visual confirmation than a small clinical specimen hatch.The representative 485 mm clear width, 871 mm transfer depth and glazed opposing doors accommodate compatible closed rodent transport containers while preserving visibility.
Hidden filter loading or unclear interlock status can delay a controlled receiving sequence.A local pressure gauge, green operating lamp, amber lock lamp and accessible single filter/fan compartment provide direct checks at the chamber.

การใช้งานทั่วไป

Receiving closed mouse or rat transport boxes across a vivarium clean-to-less-controlled boundaryBarrier transfer of compatible closed rodent cages between quarantine and designated holding routesMovement of packaged animal-care supplies through a room partition without opening a personnel doorLaboratory-animal facilities requiring a glazed, actively filtered transfer enclosure at a fixed wall opening

พารามิเตอร์ทางเทคนิค

Typical configurable construction values for the illustrated double-door dynamic animal transfer chamber are listed below.

วัสดุหลักAISI 304 stainless-steel double-wall chamber and mounting flange with colorless tempered-glass doors, charcoal EPDM gaskets and an aluminum-framed HEPA cartridge
ความหนาของแผง1.2 mm nominal stainless-steel chamber panel
ความกว้างที่มีประสิทธิภาพ485 mm nominal clear chamber width
ความยาวสูงสุดUp to 871 mm clear transfer depth in the double-door configuration
ความหนาของเหล็กหันหน้า1.2 mm nominal AISI 304 external facing
ความหนาแน่นหลัก7900 kg/m³ for representative AISI 304 stainless-steel components
การนําความร้อน15 W/(m·K) for representative AISI 304 stainless steel at room temperature
เสร็จสิ้นพื้นผิวNeutral silver satin-brushed AISI 304, colorless clear glazing, charcoal-black EPDM seals and handle, light-gray filter/fan housing, green and amber status lamps
ประเภทร่วมTwo opposing gasket-compression hinged doors with a one-door-at-a-time interlock, rear wall flange and one ceiling-supply/lower-return recirculation path
การปรับแต่งสามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน

ตัวเลือกที่มีอยู่

Alternative clear chamber dimensions for the selected closed animal transport-box formatAISI 316L stainless-steel chamber and flange constructionDimmable white or red internal LED lighting for animal-facility receiving workflowsRegional electrical supply and remote door-status or interlock signal connection