ST-IDH-019
The 720 L/day model circulates 8,000 m³/h and has a lower maximum input and net weight than the larger option.
Humidifiers & Dehumidifiers
| Brand | ST |
|---|---|
| Public model | ST-IDH-019 to ST-IDH-020 |
| Public model range | ST-IDH-019 to ST-IDH-020 |
| Control | Microcomputer automatic humidity control |
| Defrost | Automatic |
| Timer | 0–24 hours |
| Drainage | Continuous hose drainage |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Industrial Dehumidifier Series – 720 L/day to 960 L/day addresses large moisture loads with high-volume room-air circulation. It is intended for planned industrial installations where a substantial power supply and condensate route are available.
The 960 L/day model increases both airflow and maximum input relative to the 720 L/day version. The listed size is the packing dimension, so it is useful for delivery planning and must not be mistaken for an installed cabinet measurement.
MODELS AND DIMENSIONS
| Model | Dehumidification at 30°C / 80% RH (L/day) | Power supply | Maximum input power | Defrost | Humidity control and display | Airflow | Drainage | Operating temperature | Compressor protection | Packing dimensions W × D × H (mm) | Net weight | Suggested area at 2.6 m height (m²) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ST-IDH-019 | 720 L/day | 3N~380V~/50Hz | 15000w | Automatic | Microcomputer control with LED display | 8000m3/h | Water tank or continuous hose drainage | 5-38℃ | 3-minute delay protection | 1500 × 800 × 2050 | 320kg | 650-950 |
| ST-IDH-020 | 960 L/day | 380V~/50Hzthree-phase five-wire | 22000w | Automatic | Microcomputer control with LED display | 10000m3/h | Water tank or continuous hose drainage | 5-38℃ | 3-minute delay protection | 1500 × 800 × 2050 | 415kg | 900-1200 |
Dehumidification capacity is rated at the test condition stated in the table; actual removal changes with room temperature and humidity.
MODEL DIFFERENCES
The 720 L/day model circulates 8,000 m³/h and has a lower maximum input and net weight than the larger option.
The 960 L/day model raises circulation to 10,000 m³/h; its 22 kW maximum input and 415 kg weight materially change power and handling requirements.
MOISTURE REMOVAL
Moist air is cooled below its dew point so condensed water can be drained away continuously.
The defrost cycle supports operation at the stated lower room temperatures without unmanaged frost buildup.
A hose connection removes collected water without routine tank emptying during fixed installations.
APPLICATION ENVIRONMENTS
The high circulation range serves moisture removal around larger storage areas with a clear path back to the unit.
Use a dedicated equipment position where the electrical supply and condensate arrangements suit the selected industrial model.
SELECTION
The dimensional row is a packing measurement; use it for delivery planning rather than treating it as a confirmed cabinet clearance.
Higher circulation and removal also bring greater maximum input and weight; check these with the site installation provisions.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.