ST / INTEGRATED CLEANROOM PROCUREMENTEquipment / Consumables / Supporting facilities
PRODUCT / TECHNICAL DATA Humidifiers & DehumidifiersSpecifications / Configurations / Procurement

Humidifiers & Dehumidifiers

Ceiling-Mounted Constant Temperature and Humidity Unit

Product specifications

BrandST
Public modelST-CTH-C Series
InstallationCeiling mounted
Airflow arrangementFront supply / rear return; alternatives available
Power supply380 V, 3N~, 50 Hz
HumidificationElectrode humidifier; alternatives available
HeatingPTC electric heating; alternatives available

Customization availableSpecifications can be customized to your requirements.

Request a quotation

Specify the quantity and configuration in your inquiry.

Ceiling-Mounted Constant Temperature and Humidity Unit provides coordinated temperature and moisture control while leaving usable floor space clear. The indoor section is installed above the room and connected to supply and return routes, with service access planned around the ceiling structure.

Successive models increase airflow and conditioning duty, and the larger units require greater ceiling depth and structural support. The indoor and outdoor dimensions and pipe sizes in the comparison table are part of the installation choice, not just delivery details.

MODELS AND DIMENSIONS

Available capacity models

Cooling, airflow, conditioning capacity and unit dimensions for this series.
ModelAirflow arrangementCooling capacity (kW)Compressor typeCompressor input (kW)Compressor quantityFan typeAirflow (m³/h)Noise dB(A)External static pressure (Pa)Heating typeHeating power (kW)Humidification typeHumidification capacity (kg/h)Humidifier power (kW)Indoor unit length (mm)Indoor unit width (mm)Indoor unit height (mm)Indoor unit weight (kg)Outdoor unit length (mm)Outdoor unit width (mm)Outdoor unit height (mm)Outdoor unit weight (kg)Indoor/outdoor connectionLiquid pipe (mm)Gas pipe (mm)Power supply
ST-CTH-C-01Front supply/rear return; other arrangements available5.5Hermetic flexible scroll2.061Low-noise centrifugal150055Available to orderPTC electric heating; alternatives available3Electrode humidifier; alternatives available32.2130060052014584028561045Flare connectionØ6Ø12380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-02Front supply/rear return; other arrangements available7.5Hermetic flexible scroll2.21Low-noise centrifugal200055Available to orderPTC electric heating; alternatives available6Electrode humidifier; alternatives available32.2130060052015088036080055Flare connectionØ10Ø16380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-03Front supply/rear return; other arrangements available12.8Hermetic flexible scroll4.51Low-noise centrifugal300060Available to orderPTC electric heating; alternatives available9Electrode humidifier; alternatives available431400750600195930390127085Flare connectionØ12Ø19380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-04Front supply/rear return; other arrangements available15.5Hermetic flexible scroll5.21Low-noise centrifugal350060Available to orderPTC electric heating; alternatives available9Electrode humidifier; alternatives available431400750600210930390127090Flare connectionØ12Ø19380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-05Front supply/rear return; other arrangements available21.5Hermetic flexible scroll6.751Low-noise centrifugal500060Available to orderPTC electric heating; alternatives available12Electrode humidifier; alternatives available64.516009508002607507501060120Brazed connectionØ16Ø22380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-06Front supply/rear return; other arrangements available26.8Hermetic flexible scroll92Low-noise centrifugal600062Available to orderPTC electric heating; alternatives available18Electrode humidifier; alternatives available64.51600950800360930 × 2390 × 21270 × 285 × 2Brazed connectionØ12 × 2Ø19 × 2380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-07Front supply/rear return; other arrangements available32Hermetic flexible scroll10.42Low-noise centrifugal700063Available to orderPTC electric heating; alternatives available24Electrode humidifier; alternatives available861600950800390930 × 2390 × 21270 × 290 × 2Brazed connectionØ12 × 2Ø19 × 2380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-08Front supply/rear return; other arrangements available42Hermetic flexible scroll13.52Low-noise centrifugal900065Available to orderPTC electric heating; alternatives available24Electrode humidifier; alternatives available107.516009501000440750 × 2750 × 21060 × 2120 × 2Brazed connectionØ16 × 2Ø22 × 2380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-09Front supply/rear return; other arrangements available52.2Hermetic flexible scroll182Low-noise centrifugal1200065Available to orderPTC electric heating; alternatives available27Electrode humidifier; alternatives available1292000140010006101460 × 2760 × 21060 × 2200 × 2Brazed connectionØ19 × 2Ø22 × 2380 V, 3N~, 50 Hz, three-phase four-wire
ST-CTH-C-10Front supply/rear return; other arrangements available62Hermetic flexible scroll20.82Low-noise centrifugal1400068Available to orderPTC electric heating; alternatives available36Electrode humidifier; alternatives available15112200140010006901460 × 2760 × 21060 × 2230 × 2Brazed connectionØ19 × 2Ø22 × 2380 V, 3N~, 50 Hz, three-phase four-wire

Final selection requires a room sensible/latent load calculation and confirmation of the air arrangement.

MODEL DIFFERENCES

Which configuration fits the task

ST-CTH-C-01

The 5.5 kW cooling version is 1300 × 600 × 520 mm and weighs 145 kg, with 3 kW heating and 3 kg/h humidification. It is the lowest-capacity option where overhead space is limited.

ST-CTH-C-02

Cooling increases to 7.5 kW and heating to 6 kW within the same 1300 × 600 × 520 mm envelope. Humidification stays at 3 kg/h, so the change addresses thermal load rather than more moisture addition.

ST-CTH-C-03

This 12.8 kW model moves to a 1400 × 750 × 600 mm unit, adding 9 kW heating and 4 kg/h humidification. Ceiling-void depth and service access must accommodate the larger body.

ST-CTH-C-04

The 15.5 kW version supplies more cooling and airflow in the same enclosure as the 12.8 kW model. Heating and humidification stay at 9 kW and 4 kg/h, while indoor weight rises to 210 kg.

ST-CTH-C-05

At 21.5 kW, the unit is 1600 × 950 × 800 mm and 260 kg, with 12 kW heating and 6 kg/h humidification. It is the largest single-compressor option and uses brazed connections.

ST-CTH-C-06

The 26.8 kW model retains the 1600 × 950 × 800 mm envelope but uses two compressors and weighs 360 kg. Heating rises to 18 kW; the suspension design and two outdoor-unit routes change accordingly.

ST-CTH-C-07

This 32 kW version keeps the same 800 mm body height while increasing heating to 24 kW and humidification to 8 kg/h. Its 390 kg indoor weight and two-compressor layout matter to overhead support planning.

ST-CTH-C-08

The 42 kW model increases body height to 1000 mm and airflow to 9000 m³/h. Humidification reaches 10 kg/h while heating remains 24 kW, addressing a larger cooling and moisture load.

ST-CTH-C-09

At 52.2 kW, the 2000 × 1400 × 1000 mm unit weighs 610 kg, with 27 kW heating and 12 kg/h humidification. This substantial overhead assembly also requires two outdoor units and their pipe connections.

ST-CTH-C-10

The 62 kW version is the largest at 2200 × 1400 × 1000 mm and 690 kg, with 36 kW heating and 15 kg/h humidification. Listed compressor input is 20.8 kW, making both structural support and electrical coordination central to selection.

PRECISION ROOM CONDITIONING

Temperature and humidity control in one system

Cooling and heating

The controller selects cooling or electric heating to correct room temperature around the chosen setpoint.

Humidification and dehumidification

Integrated moisture control corrects both dry and humid conditions without separate portable equipment.

Continuous monitoring

The display, alarms, power-failure memory and RS485 interface support unattended rooms and central supervision.

APPLICATION ENVIRONMENTS

Combined conditioning with an overhead indoor unit

01

Space-constrained precision workrooms

The ceiling arrangement keeps floor positions available for instruments and people while conditioning room air through ducts.

02

Archives and collection rooms

Use coordinated temperature and humidity control where an overhead equipment zone and service access are part of the room layout.

03

Equipment rooms

The indoor unit can serve the required air route while its paired outdoor equipment is located separately.

SELECTION

Resolve the ceiling and duct installation first

Match the housing and supported weight

Higher-duty models change ceiling depth, footprint and structural loading; provide a service opening for the selected unit.

Select the air connection with the required pressure

Front supply and rear return are the listed arrangement; coordinate any alternative and external static-pressure requirement with the duct design.

PROCUREMENT / INQUIRY

Request a
product quotation.

Tell us the quantity and configuration you need. This product will be included automatically.

Fields marked * are required.

YOUR PRODUCTCeiling-Mounted Constant Temperature and Humidity UnitReview specifications
Useful details for this quotation

Provide room conditions and the installation layout so the unit matches the combined temperature and humidity task.

  • Room and ventilation duty
  • Temperature and humidity targets
  • Available installation space
  • Duct, power and drainage connections

We use your contact details and requirements to review your inquiry and prepare a quotation. Sending this form does not place an order.

Ceiling-Mounted Constant Temperature and Humidity Unit — product view

YOUR PURCHASING BRIEF

Inquiry list

Collect products here, then send your requirements in one inquiry.

Continue to inquiry ↗

This list is saved in this browser. Adding a product does not place an order.