ST-LPW30-040
The 40 L/h version is the entry floor-standing choice for separated analytical batches using the series ≤20 ppb TOC water specification.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW30 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Main unit dimensions | H × W × D: 1430 × 525 × 570 (mm) |
| Unit weight | 80 kg |
| Power supply and rated power | AC 220 V/50 Hz (power 75 W) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | conductivity ≤1-5 µS/cm (online monitoring) |
| Ultrapure water quality | resistivity 18.2 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | ≤1 CFU/mL |
| Particle count | ≤ 1 particle/mL |
| Heavy-metal ions | ≤0.1 ppb |
| TOC | ≤20 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW30 Series supplies RO and ultrapure water for analytical preparation from a floor-standing unit. It provides online ionic-quality monitoring together with a defined organic-background requirement.
This is the 20 ppb TOC configuration in the tall-cabinet group. It gives buyers a clear distinction from lower-TOC or ultrafiltration variants, while the three production capacities address how often water must be replenished during the working day.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW30-040 | 40 L/h at 25°C |
| ST-LPW30-060 | 60 L/h at 25°C |
| ST-LPW30-100 | 100 L/h at 25°C |
Production-rate ratings are stated at the temperature shown in the table.
MODEL DIFFERENCES
The 40 L/h version is the entry floor-standing choice for separated analytical batches using the series ≤20 ppb TOC water specification.
The 60 L/h option supplies more replenishment between repeated preparations, with no change to the listed final-water criteria.
At 100 L/h, this model provides the greatest sustained production for a busy batch schedule, rather than a different dispensing flow rating.
FEATURES AND BENEFITS
The TOC limit supports selection for methods whose tolerance is known instead of assuming all high-resistivity water is equivalent.
The cabinet format supports a separate collection point for repeated solution preparation and routine water handling.
APPLICATIONS
Match the organic and ionic limits to the method to reduce unwanted background introduced with preparation water.
SYSTEM SELECTION
Compare the method’s permitted organic background with the listed TOC value as well as final resistivity.
Select production for recurring analytical batches and reserve a floor position that keeps collection and treatment-stage maintenance accessible.
PROCUREMENT / INQUIRY
Tell us the quantity and configuration you need. This product will be included automatically.
Fields marked * are required.