ST-LPW26-040
The 40 L/h version supplies the lower-volume schedule while retaining the series UV/UF treatment and listed organic, endotoxin and enzyme-control criteria.
Cleanroom Pure Water Systems
| Brand | ST |
|---|---|
| Public model series | ST-LPW26 |
| Feed-water requirements | municipal tap water; TDS ≤200 ppm, pressure 1.0–5.0 kg/cm², temperature 5–45°C |
| Main unit dimensions | H × W × D: 1430 × 525 × 570 (mm) |
| Unit weight | 80 kg |
| Power supply and rated power | 220 V/50 Hz 75 W (voltage tolerance±10%) |
| Dispensing rate | 1.8-2.0 L/min |
| RO water quality | <1-5 µS/cm (online monitoring), desalination rate 99% |
| Ultrapure water quality | resistivity 18.2 MΩ·cm at 25°C (online monitoring, GB/T 6682-2008) |
| Microbial level | <0.01 CFU/mL |
| Particle count | < 1 particle/mL |
| Heavy-metal ions | <0.1 ppb |
| TOC | <5 ppb |
| Absorbance | ≤0.001 |
| Soluble silica | ≤0.01 mg/L |
| Endotoxin | <0.001 EU/mL |
| Evaporation residue | <1.0 mg/L |
| DNase | <3 pg/ml |
| RNase | <0.7 pg/ml |
| Protease | <0.1μg/ml |
| UF membrane cut-off | molecular-weight cut-off 5000 Da |
| UV oxidation and disinfection unit | 185/254 nm |
Customization availableSpecifications can be customized to your requirements.
Specify the quantity and configuration in your inquiry.
Laboratory Ultrapure Water System – ST-LPW26 Series combines UV treatment and ultrafiltration for laboratory preparation with several trace-contamination requirements. In addition to resistivity, the table includes TOC, endotoxin and enzyme-related values relevant to method selection.
The DNase, RNase and protease limits are useful distinctions from the more general laboratory-water configurations. A floor-standing housing and three output choices provide a dedicated preparation-water point without reducing the decision to production capacity alone.
MODELS AND DIMENSIONS
| Model | Production rate |
|---|---|
| ST-LPW26-040 | 40 L/h at 25°C |
| ST-LPW26-060 | 60 L/h at 25°C |
| ST-LPW26-100 | 100 L/h at 25°C |
Production-rate ratings are stated at the temperature shown in the table.
MODEL DIFFERENCES
The 40 L/h version supplies the lower-volume schedule while retaining the series UV/UF treatment and listed organic, endotoxin and enzyme-control criteria.
The 60 L/h model adds replenishment for preparation batches that follow more closely during an analytical or life-science session.
The 100 L/h option provides the largest recurring water volume in the series; treatment functions remain the same, so the difference is recovery capacity.
FEATURES AND BENEFITS
The separate enzyme limits help assess water for sensitive reagent and molecular-work protocols.
The listed UV and UF stages address different contamination mechanisms before water is collected.
APPLICATIONS
Use for preparation methods whose full endotoxin and water-quality requirements match this configuration.
SYSTEM SELECTION
Check the procedure’s DNase, RNase and protease requirements against this configuration together with its organic and endotoxin specifications.
Match the output model to preparation batches and leave a serviceable floor position for the UV-and-UF treatment assembly.